Especificações resumidas
-
Measuring range
0 to 2 mg/l
0.05 to 10 mg/l
0.5 to 50 mg/l -
Process temperature
4 to 40 °C (39.2 to 104 °F)
-
Process pressure
At atmospheric pressure, < 0.2 bar
Campo de aplicação
Phosphorus is the decisive factor for excessive algae and plant growth in water bodies, that's why continuous monitoring of this parameter is essential. The Liquiline System TP analyzer offers precise online measurement of total phosphorus and ensures highest process safety. Automatic calibration and cleaning save you operating costs while advanced diagnostics with remote access support you in providing process documentation to the authorities.
The Liquiline System TP analyzer monitors:
Inlet and outlet of wastewater treatment plants for documentation purposes and calculation of the cleaning capacity
Discharges of industrial wastewater treatment plants to determine discharge fees and to support the polluter-pays-principle
Process water
Benefícios
Molybdenum blue method according to EN ISO 6878:2004 guarantees direct comparability to laboratory results
Fast and easy process integration: Direct installation of self-priming version or y-strainer for bypass applications
Safety on the highest level: Software-controlled safety cover for the reactor and all heated parts. Additional safety light barrier prevents overdosing of reagents and sample.
Combination of reliable sample delivery and high-precision dosing: Peristaltic pumps are able to cope with particles in the sample. Light barriers enable precise, reproducible dosing.
Enhanced reagent lifetime thanks to optional cooling module
-
Easy upgrade of functionality to a complete measuring station - simply by adding modules and connecting Memosens sensors.
Drive connectivity: Liquiline Edge Module CYY7 transfers process data to Netilion, independently of the fieldbus. This allows remote overview and the use of IIoT services. It’s available in new products or as upgrade to installed Liquiline platforms.
Vídeos
-
The total phosphorus concentration of a liquid can be determined using chemical and thermal digestion and the colorimetric measuring principle. This video shows how this measuring principle works.
Seleção Extended
-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade
-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade
-
Produtos especializados
- Desenvolvidos para aplicações exigentes
Excelência técnica
Simplicidade
Variável
| Versões FLEX | Excelência técnica | Simplicidade |
|---|---|---|
Versão Fundamental Atende suas necessidades básicas de medição |
Excelência técnica
|
Simplicidade
|
Versão Lean Lida com seus principais processos facilmente |
Excelência técnica
|
Simplicidade
|
Seleção Extended Otimiza seus processos com tecnologias inovadoras |
Excelência técnica
|
Simplicidade
|
Versão Xpert Controla suas aplicações mais difíceis |
Excelência técnica
|
Simplicidade
Variável |
Predecessor
-
Measuring principle
Colorimetric
-
Characteristic
Analyzer for total phosphorus
-
Size
Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in -
Design
Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel -
Process temperature
4 to 40 °C (39.2 to 104 °F)
-
Ambient temperature
5 to 40 °C (41 to 104 °F)
Outdoor version: - 20 to 40 °C (-4 to 104 °F) -
Process pressure
At atmospheric pressure, < 0.2 bar
-
Sample flow rate
Min. 30 ml/min
-
Consistency of the sample
Low solid content (TS<50 mg/l), homogeneous
-
Specials
Easy upgrade to measuring station with up to four digital Memosens sensors
Automatic calibration and cleaning
User-configurable measuring, cleaning and calibration intervals
Self-priming analyzer with optical dosing unit l
Dilution module (optional)
Digital communication for remote access -
Application
Monitoring and optimization of the cleaning capacity of municipal and industrial wastewater treatment plants
Monitoring of the wastewater treatment plant outlet for documentation purposes
Monitoring and optimization of activated sludge basins -
Power supply
100 to 120 VAC / 200 to 240 VAC ± 10%
24 VDC ± 10%
50 ± 1 or 60 ± 1,2 Hz -
Output / communication
2x 0/4 to 20 mA
Webserver, Modbus, Ethernet/IP, Profibus DP -
Input
1 measuring channel
1 to 4 digitale sensor inputs for sensors with Memosens protocol (optional) -
Measuring range
0 to 2 mg/l
0.05 to 10 mg/l
0.5 to 50 mg/l -
Consumables
Reagents and standard solutions CY80TP are necessary for the operation
-
-
Informações Técnicas (TI)
TI Liquiline System CA80TP
-
Informações Técnicas (TI)
Versão em português - 05/2024New version available in EnglishAnalisador de fósforo total
EN PT 23/05/202430/11/202231/05/202114/02/202009/06/2017Idioma:
Português
Versão:
23/05/2024
Tamanho do arquivo:
4.2 MB
Nome do arquivo:
TI01264CPT_0824-00.pdf
-
-
-
Instruções de Operação (BA)
Memosens
-
Instruções de Operação (BA)
Versão em português - 05/2022New version available in EnglishEntradas do sensor com protocolo Memosens
EN PT 30/05/202228/02/2019Idioma:
Português
Versão:
30/05/2022
Tamanho do arquivo:
3.4 MB
Nome do arquivo:
BA01245CPT_0822-00.pdf
-
-
-
Instruções de Operação (BA)
BA Liquiline System CA80TP
-
Instruções de Operação (BA)
Versão em português - 05/2024New version available in EnglishAnalisador colorimétrico para fósforo total
EN PT 23/05/202430/11/202231/05/202101/04/202113/01/2020Idioma:
Português
Versão:
23/05/2024
Tamanho do arquivo:
6.2 MB
Nome do arquivo:
BA01593CPT_0624-00.pdf
-
-
-
Instruções curtas (KA)
Liquiline System CA80TP
-
Instruções curtas (KA)
Versão em português - 05/2021New version available in EnglishAnalisador colorimétrico para fósforo total
EN PT 31/05/202119/02/202006/10/201707/04/201712/05/2016Idioma:
Português
Versão:
31/05/2021
Tamanho do arquivo:
3 MB
Nome do arquivo:
KA01239CPT_0621.pdf
-
-
-
Instruções de Instalação (EA)
Kits for Analyzer CA80: Engineering parts
-
Instruções de Instalação (EA)
Versão em inglês - 06/2025New version available in EnglishKits for Analyzer CA80: Engineering parts
EN PT 30/06/2025Idioma:
Inglês
Versão:
30/06/2025
Tamanho do arquivo:
2.1 MB
Nome do arquivo:
71223028 Anleitung Kits CA8x Verfahrenstechnik 2022-08.pdf
-
-
-
Instruções de Instalação (EA)
Kit CM44x/CSXxx/CA80XX
-
Instruções de Instalação (EA)
Versão em inglês - 11/2022New version available in EnglishModule 485MB or 485DP
For Ethernet configuration, PROFIBUS DP, Modbus RS485EN PT 28/11/2022Idioma:
Inglês
Versão:
28/11/2022
Tamanho do arquivo:
1.8 MB
Nome do arquivo:
EA01447CEN_0122-00.pdf
-
-
-
Instruções de Instalação (EA)
EA Liquiline System analyzer CA80COD/TP
-
Instruções de Instalação (EA)
Versão em inglês - 10/2025New version available in EnglishWear parts
EN PT 31/10/2025Idioma:
Inglês
Versão:
31/10/2025
Tamanho do arquivo:
3.1 MB
Nome do arquivo:
EA01718CEN_0125-00.pdf
-
-
-
Instruções de Instalação (EA)
Einbauanleitung/ Installation Instructions Kit Module/Modules
-
Instruções de Instalação (EA)
Versão em inglês - 07/2014New version available in EnglishFür erweiterte Funktionalität
For extended functionalityEN PT 07/07/201425/03/201331/12/2011Idioma:
Inglês
Versão:
07/07/2014
Tamanho do arquivo:
2.4 MB
Nome do arquivo:
EA00008CA2_0314.pdf
-
-
-
Instruções de Instalação (EA)
EA Liquiline System CA8x analyzer
-
Instruções de Instalação (EA)
Versão em inglês - 08/2025New version available in EnglishCooling module
EN PT 20/08/2025Idioma:
Inglês
Versão:
20/08/2025
Tamanho do arquivo:
2.6 MB
Nome do arquivo:
EA01688CEN_0125-00.pdf
-
-
-
Instruções de Instalação (EA)
Kits for Analyzer CA8x: Housing parts
-
Instruções de Instalação (EA)
Versão em inglês - 03/2025New version available in EnglishInstallation instruction: Kits for Analyzer CA8x: Housing parts
EN PT 03/03/2025Idioma:
Inglês
Versão:
03/03/2025
Tamanho do arquivo:
957.4 KB
Nome do arquivo:
71223031 Anleitung Kits CA8x Gehaeuseteile 2022-06.pdf
-
Escolha uma das opções sugeridas
-
-- selected coding-- selected label99.999,00<%label%>
-
Procurando mais opções? Use o configurador individual para continuar.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Procurando mais opções? Use o configurador individual para continuar.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- Diagramas CAD Diagramas CAD
- Diagramas CAD
-
Preço por peça
-
<%range%><%price%>
-
- Acessórios opcionais
Configuração individual
Geralmente são fornecidos juntos
Acessórios
Produtos relacionados