The conductivity of a liquid can be measured using the conductive or toroidal measuring principles. This video shows what it is about and how these measuring principles work.

Toroidal conductivity sensor for hygienic and sterile applications

The Indumax CLS52 inductive conductivity sensor protects your products and processes in the food & beverage industry. It is equipped with a stainless steel temperature sensor that gives you an ultrafast temperature response to measure exactly in separation applications.

  • Produtos simples

  • Fácil de escolher, instalar e operar

Excelência técnica

Simplicidade

  • Produtos padrão

  • Confiável, robusto e baixa manutenção

Excelência técnica

Simplicidade

  • Produtos com tecnologia de ponta

  • Altamente funcional e prático

Excelência técnica

Simplicidade

  • Produtos especializados

  • Desenvolvidos para aplicações exigentes

Excelência técnica

Simplicidade

Variável

Versões FLEX Excelência técnica Simplicidade
  • F
  • L
  • E
  • X

Versão Fundamental

Atende suas necessidades básicas de medição

Excelência técnica
Simplicidade
  • F
  • L
  • E
  • X

Versão Lean

Lida com seus principais processos facilmente

Excelência técnica
Simplicidade
  • F
  • L
  • E
  • X

Seleção Extended

Otimiza seus processos com tecnologias inovadoras

Excelência técnica
Simplicidade
  • F
  • L
  • E
  • X

Versão Xpert

Controla suas aplicações mais difíceis

Excelência técnica
Simplicidade

Variável

  • Especificações resumidas

    • Measurement range

      0.1 to 2000 mS/cm

    • Process temperature

      Max. 125°C (short time up to 140°C)
      max. 257°F (short time up to 284°F)

    • Process pressure

      Max. 16 bar at 90 °C
      (Max. 232 psi at 194 °F)

Seleção rápida

Escolha uma das opções sugeridas
Preço de venda
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

ou

Configuração individual

Continue sua seleção entre todas as opções possíveis
  • Benefícios

    • Engineered for quick temperature response

    • Hygienic design avoids contamination

    • Suitable for cleaning-in-place (CIP) and sterilization-in-place (SIP)

    • Low risk of soiling due to encapsulated sensor

    • Insensitive to polarization

  • Campo de aplicação

    Indumax CLS52 measures toroidal conductivity especially in food & beverage applications, where a fast temperature response is needed, such as:

    • Alkaline/acid concentration control in remaking

    • Phase separation of product/water and product/product...

Características e especificações

Voltar

Details

  • Measuring principle

    Inductive

  • Application

    Food, pharmaceuticals

  • Characteristic

    Hygienic inductive measuring cell for conductivity measurements, concentration control, CIP-control, cleaning and phase separation.

  • Measurement range

    0.1 to 2000 mS/cm

  • Measuring principle

    Inductive conductivity measurement.

  • Design

    Hygienic inductive conductivity cell with an outside temperature sensor for a faster temperature reading.

  • Material

    Sensor: PEEK
    Heat contact nut: stainless steel 1.4435
    Sealing: Chemraz

  • Dimension

    Coil: outside diameter: appr. 47 mm inside diameter: appr. 15 mm

  • Process temperature

    Max. 125°C (short time up to 140°C)
    max. 257°F (short time up to 284°F)

  • Process pressure

    Max. 16 bar at 90 °C
    (Max. 232 psi at 194 °F)

  • Temperature sensor

    Integrated Pt100 in a heat contact nut

  • Ex certification

    ATEX

  • Connection

    Process connections: dairy fitting, Clamp, thread 1,5", Varivent, APV, Perlick, SMS cable: fixed cable connection.

  • Ingres protection

    IP67

  • Additional certifications

    Calibration certification.

Documentos / Manuais / Software

Acessórios / peças sobressalentes

Nr
Order code
Specification
    • Order code 51500753

      Accessories for cable CLS 50 / CLS 52

    • Order code 50081902

      Calibration solution CLY11-A, 74,0 uS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO

    • Order code 50081903

      Calibration solution CLY11-B,149,6 uS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO.

    • Order code 50081904

      Calibration solution CLY11-C,1,406mS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO

    • Order code 50081905

      Calibration solution CLY11-D,12,64 mS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM to NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO

    • Order code 50081906

      Calibration solution CLY11-E,107,00mS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO