The Cerabar PMP51 digital pressure transmitter with metal membrane is typically used in process and hygiene applications for pressure, level, volume or mass measurement in liquids or gases. PMP51 is designed for high pressure applications up to 400bar. Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. SIL2 according to IEC 61508 and IEC 61511.
Single chamber aluminum or stainless steel (316L) housing.
Process connections: Threads, flanges or hygienic connections
Process temperature: -40 to +130°C (-40 to +266°F), 150°C (302°F) for 1h
Measuring range: -1/0 up to +400bar (-15/0 up to +6,000psi)
Accuracy: ±0.1%, "Platinum" ±0.075%
International explosion protection certificates, SIL, hygienic approvals, marine approvals
Benefícios
Accurate measurement of the process value even in the case of changing process temperature
Process safety assured with small flush mounted process connections in hygienic applications
For process pressure monitoring up to SIL2, certified to IEC 61508 and IEC 61511
Modular concept for easy replacement of display or electronics
Easy menu-guided commissioning via on-site display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
Seamless and independent system integration (HART/PA/FF)
Available with mounted manifolds: always fit, always tested for leaks
Vídeos
Comunicação IO-Link
Comunicação IO-Link ajuda a digitalizar sua indústria
Kemira, a global chemicals company, needs accurate monitoring of level and temperature for polymer manufacturing. They use instrumentation with Bluetooth for safe and easy access to process data.
Protolaunch utiliza medidores de vazão e sensores de nível da Endress+Hauser em uma instalação de testes de propulsão de foguetes em Buckinghamshire para demonstrar o desempenho dos sistemas e componentes de propulsão.
Torishima projeta e constrói grandes sistemas de água de resfriamento para clientes no Oriente Médio, confiando na instrumentação da Endress+Hauser pela qualidade e desempenho de seus produtos.
Global crop protection and seed technology company Nufarm reduces measurement uncertainty to less than 1% with new-generation 80 GHz radar level sensors
Bonumose decided to enhance, automate and digitalize its tagatose sweetener manufacturing process with Endress+Hauser instrumentation to reach its company growth goals
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus IO-Link
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI
Safety approvals
SIL
Design approvals
EN 10204-3.1 NACE MR0175, MR0103 AD2000
Hygienic approvals
3A, EHEDG CoC ASME-BPE
Marine approval
GL/ ABS/ LR/ BV/ DNV
Drinking water approvals
NSF
Options
Local display
Successor
PMP51B
Application limits
Measuring cell: Metal welded If pressurized, possibly use differential pressure meas-urement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure
Cerabar M / Deltabar M / Deltapilot M, Operating Instructions
FOUNDATION Fieldbus
Instruções de Operação (BA)
Versão em português - 08/2024
New version available in English
Cerabar M PMC51, PMP51, PMP55 Pressure transmitter Deltabar M PMD55 Differential pressure transmitter Deltapilot M FMB50 Hyd rostatic pressure transmitter
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Usamos cookies para melhorar sua experiência de navegação, coletamos estatísticas para otimizar a funcionalidade do site e entregar anúncios e conteúdo personalizados.
Ao selecionar "Aceitar todos", você consente nosso uso de cookies.
Para mais detalhes, revise nossa Política de cookies .