Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
For solids and semi-solids analysis, the Raman Rxn-20 probe reigns supreme. Its state-of-the-art, stainless-steel probe design produces representative, focus-free, quantitative Raman measurements. The Rxn-20 probe illuminates a large surface area and eliminates the need to align the probe for surface roughness. It provides heterogenous solids sampling via volumetric analysis, which is highly useful for measuring tablets, capsules, food solids, and polymer beads.
Chemicals: final product quality, blend impurities, crystallinity, raw materials
Polymers: extruded pellet quality, crystallinity, density, raw materials
Pharmaceutical: crystallinity, polymorphism, granulation, blend uniformity, content uniformity, coating, tableting
Food & Beverage: quality of dairy solids, meat and fish composition
Non-contact measurement of heterogeneous solids for better representation
Improved process control and efficiency through faster measurements
Non-destructive measurements from a distance
Reproducible sampling
Sampling flexibility with a variety of focus-free and immersion Rxn-20 accessory optics
No need to align probe for surface roughness
Surface and deep layer (volumetric) analysis
Produtos com tecnologia de ponta
Excelência técnica
Simplicidade
Produtos com tecnologia de ponta
Excelência técnica
Simplicidade
Produtos especializados
Excelência técnica
Simplicidade
Variável
| Versões FLEX | Excelência técnica | Simplicidade |
|---|---|---|
Versão Fundamental Atende suas necessidades básicas de medição |
Excelência técnica
|
Simplicidade
|
Versão Lean Lida com seus principais processos facilmente |
Excelência técnica
|
Simplicidade
|
Seleção Extended Otimiza seus processos com tecnologias inovadoras |
Excelência técnica
|
Simplicidade
|
Versão Xpert Controla suas aplicações mais difíceis |
Excelência técnica
|
Simplicidade
Variável |
Design do sistema e especificações para os acessórios da sonda Rxn-20
| EN | PT | ||
|
24/03/2025
|
|
|
|
|
03/08/2022
|
|
|
|
Idioma: |
Português |
|
Versão: |
24/03/2025 |
|
Tamanho do arquivo: |
810.8 KB |
|
Nome do arquivo: |
TI01636CPT_0222.pdf |
Design do sistema e especificações para a sonda Raman Rxn-20
| EN | PT | ||
|
24/03/2025
|
|
|
|
|
13/12/2024
|
|
|
|
|
03/08/2022
|
|
|
|
|
14/09/2021
|
|
|
|
Idioma: |
Português |
|
Versão: |
24/03/2025 |
|
Tamanho do arquivo: |
719.9 KB |
|
Nome do arquivo: |
TI01631CPT_0323.pdf |
Detalhes de comissionamento, operação e manutenção da sonda Raman Rxn‑20
| EN | PT | ||
|
31/01/2025
|
|
|
|
|
02/12/2024
|
|
|
|
|
03/08/2022
|
|
|
|
|
14/09/2021
|
|
|
|
Idioma: |
Português |
|
Versão: |
31/01/2025 |
|
Tamanho do arquivo: |
1.5 MB |
|
Nome do arquivo: |
BA02167CPT_0323.pdf |
Detalhes de comissionamento, operação e manutenção
para os acessórios da sonda Rxn‑20
| EN | PT | ||
|
27/02/2025
|
|
|
|
|
03/08/2022
|
|
|
|
|
14/09/2021
|
|
|
|
Idioma: |
Português |
|
Versão: |
27/02/2025 |
|
Tamanho do arquivo: |
418.8 KB |
|
Nome do arquivo: |
BA02172CPT_0222.pdf |
Guia de início rápido para a sonda Raman Rxn-20
| EN | PT | ||
|
30/01/2025
|
|
|
|
|
02/12/2024
|
|
|
|
|
03/08/2022
|
|
|
|
|
14/09/2021
|
|
|
|
Idioma: |
Português |
|
Versão: |
30/01/2025 |
|
Tamanho do arquivo: |
721.1 KB |
|
Nome do arquivo: |
KA01547CPT_0323.pdf |
Guia de início rápido para acessórios da sonda Rxn-20
| EN | PT | ||
|
02/12/2024
|
|
|
|
|
03/08/2022
|
|
|
|
Idioma: |
Português |
|
Versão: |
02/12/2024 |
|
Tamanho do arquivo: |
429.3 KB |
|
Nome do arquivo: |
KA01552CPT_0222.pdf |
Certificações para áreas classificadas e instruções de instalação
para a sonda Raman Rxn-20
| EN | PT | ||
|
21/06/2024
|
|
|
|
|
08/08/2023
|
|
|
|
Idioma: |
Português |
|
Versão: |
08/08/2023 |
|
Tamanho do arquivo: |
921.2 KB |
|
Nome do arquivo: |
XA02747CPT_0323.pdf |
A list of published technical articles related to Biopharma 4.0
topics with recommendations from Life Science industry experts
at Endress+Hauser.
|
Idioma: |
Inglês |
|
Versão: |
26/06/2025 |
|
Tamanho do arquivo: |
363.4 KB |
|
Nome do arquivo: |
PU01611CEN_0125.pdf |
Découvrez comment les systèmes de spectroscopie Raman
sont installés en toute sécurité dans des zones explosibles.
Cet article explique les risques d’ignition optique,
les concepts de protection et comment ATEX, IECEx
et les normes nordaméricaines influent sur la conception
et l’installation conformes des systèmes Raman.
|
Idioma: |
French |
|
Versão: |
19/08/2026 |
|
Tamanho do arquivo: |
2 MB |
|
Nome do arquivo: |
PU01633CFR_0126-HD-ecran-ppp.pdf |
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).
|
Idioma: |
Inglês |
|
Versão: |
19/04/2022 |
|
Tamanho do arquivo: |
1.1 MB |
|
Nome do arquivo: |
PU01447CEN_0222.pdf |