Tente buscar por palavras-chaves, código de pedido ou produto ou número de série, por exemplo, "CM442" ou "informações técnicas"
Insira pelo menos 2 caracteres para iniciar a busca.
  • Histórico

Analog conductivity sensor
Indumax CLS54

Analog conductivity sensor
Indumax CLS54 ©Endress+Hauser
Analog conductivity sensor
Indumax CLS54 ©Endress+Hauser
Analog conductivity sensor
Indumax CLS54 ©Endress+Hauser
Analog conductivity sensor
Indumax CLS54 ©Endress+Hauser

The conductivity of a liquid can be measured using the conductive or toroidal measuring principles. This video shows what it is about and how these measuring principles work.

Toroidal conductivity sensor for hygienic and sterile applications

The Indumax CLS54 inductive conductivity sensor protects all of your products and processes that must meet the strictest hygienic and sterile demands. Its outstanding performance combined with a unique hygienic design ensures highest safety and quality of your products.

  • Produtos simples

  • Fácil de escolher, instalar e operar

Excelência técnica

Simplicidade

  • Produtos padrão

  • Confiável, robusto e baixa manutenção

Excelência técnica

Simplicidade

  • Produtos com tecnologia de ponta

  • Altamente funcional e prático

Excelência técnica

Simplicidade

  • Produtos especializados

  • Desenvolvidos para aplicações exigentes

Excelência técnica

Simplicidade

Variável

Versões FLEX Excelência técnica Simplicidade
  • F
  • L
  • E
  • X

Versão Fundamental

Atende suas necessidades básicas de medição

Excelência técnica
Simplicidade
  • F
  • L
  • E
  • X

Versão Lean

Lida com seus principais processos facilmente

Excelência técnica
Simplicidade
  • F
  • L
  • E
  • X

Seleção Extended

Otimiza seus processos com tecnologias inovadoras

Excelência técnica
Simplicidade
  • F
  • L
  • E
  • X

Versão Xpert

Controla suas aplicações mais difíceis

Excelência técnica
Simplicidade

Variável

  • Especificações resumidas

    • Measurement range

      100 µS/cm - 2000 mS/cm Cell constant k: 6,3 1/cm

    • Process temperature

      Process temperature: -10°C - +125°C
      (14°F - 257°F)
      Sterilisation: 150°C/5 bar (max. 60 min.)
      (302°F / 72.5 psi)

    • Process pressure

      12 bar(174 psi)/20°C(68°F)
      8 bar(116 psi)/125°C(257°F)

Seleção rápida

Escolha uma das opções sugeridas
Preço de venda
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

ou

Configuração individual

Continue sua seleção entre todas as opções possíveis
  • Benefícios

    • Unique hygienic design avoids contamination

    • With all hygienic certificates required in hygienic applications

    • Food grade virgin PEEK body without joints nor crevices

    • Certified biocompatibility according to USP class VI

    • Suitable for cleaning-in-place (CIP)...

  • Campo de aplicação

    Indumax CLS54 measures toroidal conductivity in hygienic food & beverage and life science applications, such as:

    • Phase separation of product/water and product/product mixtures in pipe systems

    • Control of CIP (cleaning in place) processes in the return...

Características e especificações

Voltar

Details

  • Measuring principle

    Inductive

  • Application

    Food, beverage and pharmaceutical industries and in biotechnology.

  • Characteristic

    Specifically intended for use in hygienic applications and especially suitable for following applications:
    Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring.

  • Measurement range

    100 µS/cm - 2000 mS/cm Cell constant k: 6,3 1/cm

  • Measuring principle

    Inductive conductivity measurement

  • Design

    Hygienic design with food-grade virgin PEEK body in jointless and creviceless design including all hygienic certifications.

  • Material

    In contact with medium: Virgin PEEK
    Surface roughness: Ra<0.9µm

  • Process temperature

    Process temperature: -10°C - +125°C
    (14°F - 257°F)
    Sterilisation: 150°C/5 bar (max. 60 min.)
    (302°F / 72.5 psi)

  • Process pressure

    12 bar(174 psi)/20°C(68°F)
    8 bar(116 psi)/125°C(257°F)

  • Temperature sensor

    Pt1000 (class A)with a temperature response time T90 < 27s.

  • Ex certification

    ATEX II G EEx ia IIc T3/T4/T6
    FM/CSA IS NI CL.I,II,III,Div.1&2 group A-G in connection with the transmitter CM42.

  • Connection

    Dairy pipe, Aseptic-fitting, Clamp ISO 2852, SMS-2", Varivent N DN 40-125, Neumo Biocontrol D50.

  • Ingres protection

    IP68/NEMA6P

  • Additional certifications

    FDA, EHEDG, 3-A, Biological reactivity (USP class VI part 87 and 88)

Documentos / Manuais / Software

Acessórios / peças sobressalentes

Nr
Order code
Specification
    • Order code 50081902

      Calibration solution CLY11-A, 74,0 uS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO

    • Order code 50081903

      Calibration solution CLY11-B,149,6 uS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO.

    • Order code 50081904

      Calibration solution CLY11-C,1,406mS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO

    • Order code 50081905

      Calibration solution CLY11-D,12,64 mS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM to NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO

    • Order code 50081906

      Calibration solution CLY11-E,107,00mS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO

    • Order code 71183688

      Extention cable CLK 6