Tente buscar por palavras-chaves, código de pedido ou produto ou número de série, por exemplo, "CM442" ou "informações técnicas"
Insira pelo menos 2 caracteres para iniciar a busca.
  • Histórico

RIA45
Process meter with control unit

Process panel meter RIA45 ©Endress+Hauser

Multifunctional panel mounted process meter for monitoring and indication of analog measured values

Analog measured values are indicated, evaluated and calculated by the process meter. With the integrated loop power supply two-wire sensors can be powered. The universal inputs enable the connection of current, voltage, RTDs and TCs. Limit values can be monitored and relays can be switched. Via analog outputs process signals can be forwarded. The integrated application package "differential pressure" allows the quick and easy commissioning for differential pressure applications.

  • Produtos simples

  • Fácil de escolher, instalar e operar

Excelência técnica

Simplicidade

  • Produtos padrão

  • Confiável, robusto e baixa manutenção

Excelência técnica

Simplicidade

  • Produtos com tecnologia de ponta

  • Altamente funcional e prático

Excelência técnica

Simplicidade

  • Produtos especializados

  • Desenvolvidos para aplicações exigentes

Excelência técnica

Simplicidade

Variável

Versões FLEX Excelência técnica Simplicidade
  • F
  • L
  • E
  • X

Versão Fundamental

Atende suas necessidades básicas de medição

Excelência técnica
Simplicidade
  • F
  • L
  • E
  • X

Versão Lean

Lida com seus principais processos facilmente

Excelência técnica
Simplicidade
  • F
  • L
  • E
  • X

Seleção Extended

Otimiza seus processos com tecnologias inovadoras

Excelência técnica
Simplicidade
  • F
  • L
  • E
  • X

Versão Xpert

Controla suas aplicações mais difíceis

Excelência técnica
Simplicidade

Variável

  • Especificações resumidas

    • Input

      2 x universal (U, I, R, RTD, TC)

    • Output

      1 x loop power supply

    • Output

      2 x analogue output (I, U)
      1 x loop power supply

    • Display

      Multicolor backlight LCD
      White/black/yellow
      Bargraph
      Unit
      TAG
      Alarm warning in plain text

    • Power Supply

      20...250V AC/DC

please wait Loading alternative products

Seleção rápida

Escolha uma das opções sugeridas
Preço de venda
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

ou

Configuração individual

Continue sua seleção entre todas as opções possíveis
  • Benefícios

    • 5-digit 7-segment LC display, backlit

    • 1 or 2 universal inputs

    • 2 relays (optional)

    • Min./max. value saved

    • 1 or 2 calculated values and linearization table

    • Digital status output (Open Collector)

    • SIL2 approval (optional); marine approval

  • Campo de aplicação

    The RIA45 panel meter exhibits a display, analog inputs for process and status signals, analog and digital outputs, and an interface for configuration. Connected sensors can be powered by the integrated LPS. All measured and calculated values are...

Details

  • Measuring principle

    Indicators with control unit

  • Measuring principle

    Process meter with control unit

  • Function

    Display

    Loop power supply

    Transmitter functionality

    Barrier

    Signal isolation

    Calculation

    Limit alarm

  • Display

    Multicolor backlight LCD

    White/black/yellow

    Bargraph

    Unit

    TAG

    Alarm warning in plain text

  • Power Supply

    20...250V AC/DC

  • Input

    2 x universal (U, I, R, RTD, TC)

  • Output

    1 x loop power supply

  • Output

    1 x loop power supply

  • Software functions

    Linearization

    Minimum value per channel

    Maximum value per channel

    Calculation

    Band value monitoring

  • Certificates

    ATEX II (1)GD[Ex ia] 4C

    CSA AIS, NI/I/2 ABCDEFG/T4

    FM AIS, NI/I/2 ABCDEFG/T4

    marine approval

    UR C/US

  • SIL

    2

  • Panel mounting

    panel mounting

  • Measuring principle

    Display

  • Function

    Display

    Loop power supply

    Transmitter functionality

    Barrier

    Signal isolation

    Calculation

    Limit alarm

  • Certification

    ATEX II (1)GD[Ex ia] 4C

    CSA AIS, NI/I/2 ABCDEFG/T4

    FM AIS, NI/I/2 ABCDEFG/T4
    Marine approval

    UR C/US

  • Input

    2 x universal (U, I, R, RTD, TC)

  • Output

    2 x analogue output (I, U)

    1 x loop power supply

  • Relay output

    2 x changeover contact

    1 x open collector

  • Auxiliary power supply / Loop power supply

    20...250V AC/DC

  • Dimensions (wxhxd)

    Panel housing:

    96 x 48 x 175 mm

    (3.78" x 1.89" x 6.89")

  • Software

    Linearization

    Minimum value per channel

    Maximum value per channel

    Calculation

    Band value monitoring

  • Operation

    3 keys

    Interface CDI to USB at PC + configuration software FieldCare

  • Display

    Multicolor backlight LCD

    White/black/yellow

    Bargraph

    Unit

    TAG

    Alarm warning in plain text

Documentos / Manuais / Software

Acessórios / peças sobressalentes

Nr
Order code
Specification
  • Predecessor