Liquiline M CM42 is the robust transmitter for pH/ORP, conductivity or oxygen measurement in all process applications. It is the best choice for demanding environments be it hygienic applications, hazardous areas or functional safety areas. Liquiline’s intuitive operating concept simplifies commissioning, handling, and maintenance saving you time every day. Easy switching of parameters and seamless system integration give you the flexibility to adapt it exactly to your measuring task.
The Liquiline CM42 transmitter is suitable for all process applications, for example in these industries and their utilities:
Chemicals
Food & Beverages
Life Sciences
Power & Energy
Oil & Gas
Primaries & Metal
Liquiline CM42 features the following protocols and interfaces:
0/4...20 mA
HART
PROFIBUS PA
FOUNDATION Fieldbus
With its international explosion protection approvals, such as IECEx, ATEX, FM, CSA, TIIS and NEPSI, the transmitter is suitable for hazardous area use.
Benefícios
Simple commissioning with quick setup and navigator
The Memosens technology allows plug & play with pre-calibrated Memosens sensors
Less storage thanks to modular design
Predictive maintenance system detects when a sensor has to be cleaned, calibrated or replaced
A medição de interface em espessantes é feita manualmente, enquanto a medição de turbidez é feita através da obtenção de amostras enviadas ao laboratório. Com a Endress+Hauser existe uma solução automatizada.
From time consuming sample analysis to real-time monitoring of critical parameters in fermentation processes thanks to complete solutions from hardware to development and analytical services.
O painel de desinfecção oferece à cervejaria Maisel um sistema de medição de desinfecção estável, confiável e de baixa manutenção que permite dosagem ideal e reduz os custos.
Ao escolher a plataforma Liquiline, você opta por gastar menos dinheiro na manutenção do estoque, economizar tempo de instalação e obter segurança da operação!
Um alto grau de automação combinado com uma mão de obra qualificada garante uma alta eficiência de produção de várias versões do equipamento. Nós adaptamos o seu equipamento para aquilo que você precisa.
Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas
Characteristic
Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering
Measuring principle
Potentiometric pH measurement
Design
Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol
Material
Plastic or stainless steel housing with EPDM sealings
Dimension
Plastic housing: 144 x 144 x 148 mm 5.67 x 5.67 x 5.83 inch Stainless Steel: 174 x 174 x 134 mm 6.85 x 6.85 x 5.28 inch
Temperature sensor
Applicable: Pt100, Pt1000, NTC 30K
Ex certification
: ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex
Ingress protection
IP66/67, NEMA 4X
Input
One channel transmitter for Memosens and analog (pH, ORP, conductivity)
Output / communication
1/2 x 4 to 20 mA, HART, Profibus PA, FF Additional second output possible, also later
Measuring principle
Sensor ORP / Redox
Application
Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas
Characteristic
Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering
Measuring principle
ORP measurement
Design
Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol
Material
Plastic or stainless steel housing with EPDM sealings
Dimension
Plastic housing: 144 x 144 x 148 mm 5.67 x 5.67 x 5.83 inch Stainless Steel: 174 x 174 x 134 mm 6.85 x 6.85 x 5.28 inch
Temperature sensor
Applicable: Pt100, Pt1000, NTC 30K
Ex certification
ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex
Ingress protection
IP66/67, NEMA 4X
Input
One channel transmitter for Memosens and analog (pH, ORP, conductivity)
Output / communication
1/2 x 4 to 20 mA, HART, Profibus, FF Additional second output possible, also later
Measuring principle
Conductive
Application
Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas
Characteristic
Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering
Measuring principle
Resistance measurement
Design
Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol
Material
Plastic or stainless steel housing with EPDM sealings
Dimension
Plastic housing: 144 x 144 x 148 mm 5.67 x 5.67 x 5.83 inch Stainless Steel: 174 x 174 x 134 mm 6.85 x 6.85 x 5.28 inch
Temperature sensor
Applicable: Pt100, Pt1000
Ex certification
ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex
Ingress protection
IP66/67, NEMA 4X
Input
One channel transmitter for Memosens and analog (pH, ORP, conductivity)
Output / communication
1/2 x 4 to 20 mA, HART, Profibus PA, FF Additional second output possible, also later
Measuring principle
Amperometric oxygen measurement
Application
Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas
Characteristic
Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering
Measuring principle
Connection of oxygen sensors with Memosens coupling
Design
Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol
Material
Plastic or stainless steel housing with EPDM sealings
Dimension
Plastic housing: 144 x 144 x 148 mm 5.67 x 5.67 x 5.83 inch Stainless Steel: 174 x 174 x 134 mm 6.85 x 6.85 x 5.28 inch
Ex certification
ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex
Ingress protection
IP66/67, NEMA4X
Input
One channel transmitter for Memosens and analog (pH, ORP, conductivity)
Output / communication
1/2 x 4 to 20 mA, HART, Profibus PA, FF Additional second output possible, also later
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Usamos cookies para melhorar sua experiência de navegação, coletamos estatísticas para otimizar a funcionalidade do site e entregar anúncios e conteúdo personalizados.
Ao selecionar "Aceitar todos", você consente nosso uso de cookies.
Para mais detalhes, revise nossa Política de cookies .