©Endress+Hauser
iTHERM TT412 Imperial Hygienic Thermowell with QuickNeck
©Endress+Hauser
iTHERM TT412 Imperial Hygienic Thermowell with Tri-Clamp process connection
©Endress+Hauser
iTHERM TT412 Imperial Hygienic Thermowell with QuickNeck and weld-in adapter
©Endress+Hauser
TT412 elbow thermowell and iTHERM QuickNeck
©Endress+Hauser
Half-section view of the TT412 elbow thermowell, with the thermowell projecting straight into one side of the pipe bend
Especificações resumidas
Max. process pressure (static)
Maximum standard immersion length
Campo de aplicação
Best applicable for use in hygienic or aseptic pipes and containers or tanks even with very small immersion lengths. It meets increased protection requirements of the temperature sensor regarding physical and chemical effects. Ideally suited to all measuring points that require regular re-calibration by simply replacing the insert in closed processes.
Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
Pressure range up to 40 bar (580 psi)
For increased protection requirements of the temperature sensor regarding physical and chemical effects
For use in pipes and containers or tanks
Ideally suited to all measuring points that require regular recalibration by simply replacing the insert in closed processes
Benefícios
iTHERM QuickNeck – cost and time savings thanks to simple, tool-free recalibration of the insert used
All common hygienic process connections
International certification: hygiene standards as per 3-A, EHEDG, ASME BPE, FDA, TSE Certificate of Suitability
Fast response time owing to reduced tips with thin walls
State of the art Tee and Elbow thermowells, without welds and dead legs and with best in class hygienic design
Seleção Extended
Excelência técnica
Simplicidade
©Endress+Hauser
Produtos simples
Fácil de escolher, instalar e operar
Excelência técnica
Simplicidade
Produtos padrão
Confiável, robusto e baixa manutenção
Excelência técnica
Simplicidade
Excelência técnica
Simplicidade
Produtos especializados
Desenvolvidos para aplicações exigentes
Excelência técnica
Simplicidade
Versões FLEX
Excelência técnica
Simplicidade
Versão Fundamental
Atende suas necessidades básicas de medição
Excelência técnica
Simplicidade
Versão Lean
Lida com seus principais processos facilmente
Excelência técnica
Simplicidade
Seleção Extended
Otimiza seus processos com tecnologias inovadoras
Excelência técnica
Simplicidade
Versão Xpert
Controla suas aplicações mais difíceis
Excelência técnica
Simplicidade
Loading alternative products
Histórias de sucesso
Autoclaves médicas
Nova tecnologia de sensores automatiza recalibrações para reduzir riscos em esterilizações em lote. Saiba mais!
Leia o artigo completo
Characteristic / Application
imperial style hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA) hygienic process connections iTHERM QuickNeck for easy and cost saving recalibration
Maximum standard immersion length
Process connection
weld in adaptor clamp connections acc. to ISO2852 thread acc. to ISO 228 for liquiphant adaptor APV Inline Varivent Tee and elbow thermowells DIN11865
Thermowell root diameter
1/4" (6,35 mm) 3/8" (9,525 mm) 1/2" (12,7mm)
Wetted part finishing (Ra)
< 30 μinch (0,76 μm) < 15 µinch(0,38 μm) < 15 μinch (0,38 µm) electropolished
Temperature range
-200...650 °C (-328...1.202 °F)
Max. process pressure (static)
Max. process pressure at 400 °C
depends on process connection
Mais baixados
iTHERM TT412
Versão em português - 07/2022
Sensor de temperatura - poço para termoelemento para aplicações
higiênicas e assépticas
EN
PT
DE ES FR IT JA RU ZH
31/08/2025
29/07/2022
13/01/2021
31/10/2018
04/08/2017
Idioma:
Português
Versão:
29/07/2022
Tamanho do arquivo:
1.2 MB
Nome do arquivo:
TI01350TPT_0422-00.pdf
TI Weld-in adapter, process adapter and flanges
Versão em português - 12/2024
Level, pressure and temperature measurement
EN
PT
DE ES FR IT JA PL RU ZH
06/12/2024
04/04/2024
25/03/2024
15/09/2023
28/10/2021
Idioma:
Português
Versão:
06/12/2024
Tamanho do arquivo:
3 MB
Nome do arquivo:
TI00426FPT_2624.pdf
13 documentos
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN
PT
Alemão Espanhol French Italiano Japonês Polonês Russo Chinês
06/12/2024
04/04/2024
25/03/2024
15/09/2023
28/10/2021
Idioma:
Português
Versão:
06/12/2024
Tamanho do arquivo:
3 MB
Nome do arquivo:
TI00426FPT_2624.pdf
Sensor de temperatura - poço para termoelemento para aplicações higiênicas e assépticas
EN
PT
Alemão Espanhol French Italiano Japonês Russo Chinês
31/08/2025
29/07/2022
13/01/2021
31/10/2018
04/08/2017
Idioma:
Português
Versão:
29/07/2022
Tamanho do arquivo:
1.2 MB
Nome do arquivo:
TI01350TPT_0422-00.pdf
Technical documentation in other languages
Idioma:
Inglês
Versão:
14/07/2021
Tamanho do arquivo:
478.5 KB
Nome do arquivo:
SD02429R09EN_0121.pdf
SD Hygienic process connection types
Supplement to TM311, TM371, TM372, TM401, TM411, TM402, TM412, TT411, TT412, TE411, TK40, TMR35, DTT35, TTR35
Idioma:
Inglês
Versão:
15/09/2023
Tamanho do arquivo:
800.3 KB
Nome do arquivo:
SD03119TEN_0123-00.pdf
Product family: Accessories: Pipe thermowell, Magphant, Process RTD hygienic, RTD thermometer
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35- Declaration number: HE_01097_03.24 Manufacturer specification: Food hygiene
Idioma:
Inglês
Versão:
24/10/2024
Tamanho do arquivo:
112.3 KB
Nome do arquivo:
HE_01097_03.24_en.pdf
Product family: Accessories: Pipe thermowell, Accessories: Inserts,
PROCESS RTD HYGIENIC, RTD thermometer
Product root: TK40-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TS111-, TS212-, TT411-, TT412- Declaration number: HE_00886_01.17 Additional information: TSE compliance, animal fat free
Idioma:
Inglês
Versão:
23/10/2017
Tamanho do arquivo:
160.7 KB
Nome do arquivo:
HE_00886_0117.pdf
Product family: Accessories: Pipe thermowell, Magphant, Process RTD hygienic, RTD thermometer
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35- Declaration number: HE_00099_05.15 Manufacturer specification: Food hygiene, 10/2011, 1935/2004
Idioma:
Inglês
Versão:
07/12/2020
Tamanho do arquivo:
1.7 MB
Nome do arquivo:
HE_00099_05.15.pdf
Product family: Accessories: Bar stock thermowell, Accessories: Pipe thermowell, Accessories: Inserts, Magphant, Process RTD general
purpose, Process RTD hygienic, RTD thermometer
Product root: DTT31-, DTT35-, TK40-, TM101-, TM111-, TM121-, TM131-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TS111-, TS212-, TT131-, TT151-, TT411-, TT412- Declaration number: HE_01494_01.21 Manufacturer specification: Food hygiene Additional information: BSE, TSE
Idioma:
Inglês
Versão:
27/07/2023
Tamanho do arquivo:
266 KB
Nome do arquivo:
HE_00886_07_17.pdf
Product family: Process RTD hygienic
Product root: TK40-, TM401-, TM402-, TM411-, TM412-, TS111-, TS112-, TT411-, TT412- Declaration number: MD-12028A-9
Idioma:
Inglês
Versão:
10/01/2013
Tamanho do arquivo:
872.7 KB
Nome do arquivo:
MD-12028a_09_e.pdf
Product family: Accessories: Pipe thermowell, Process RTD hygienic, RTD thermometer
Product root: TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TT411-, TT412- Declaration number: FDA_00127_04.25
Idioma:
Inglês
Versão:
20/07/2025
Tamanho do arquivo:
422.5 KB
Nome do arquivo:
FDA_00127_04.25.pdf
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
Spare parts kit sealing iTHERM QuickNeck
Código de pedido
71182607
Sua privacidade é muito importante
Usamos cookies para melhorar sua experiência de navegação, coletamos estatísticas para otimizar a funcionalidade do site e entregar anúncios e conteúdo personalizados.
Ao selecionar "Aceitar todos", você consente nosso uso de cookies.
Para mais detalhes, revise nossa Política de cookies .
Personalizar
Aceitar apenas o essencial
Aceitar todos