Tente buscar por palavras-chaves, código de pedido ou produto ou número de série, por exemplo, "CM442" ou "informações técnicas"
Insira pelo menos 2 caracteres para iniciar a busca.
  • Histórico

Radiometric
Interface measurement
Source Container FQG63

Source Container FQG63 ©Endress+Hauser

Radiometric measuring principle

Radiometric interface measurement

Lightweight radiation source container with flexible extension element

The FQG63 source container is designed to hold the radioactive source during radiometric level, density and interface measurement. The radiation is damped in all directions as long as the source container is switched off. This guarantees highest safety for the personnel and a reliable measurement. If the source is switched on and lowered down into the process tank, it emits the radiation into all directions.

  • Produtos simples

  • Fácil de escolher, instalar e operar

Excelência técnica

Simplicidade

  • Produtos padrão

  • Confiável, robusto e baixa manutenção

Excelência técnica

Simplicidade

  • Produtos com tecnologia de ponta

  • Altamente funcional e prático

Excelência técnica

Simplicidade

  • Produtos especializados

  • Desenvolvidos para aplicações exigentes

Excelência técnica

Simplicidade

Variável

Versões FLEX Excelência técnica Simplicidade
  • F
  • L
  • E
  • X

Versão Fundamental

Atende suas necessidades básicas de medição

Excelência técnica
Simplicidade
  • F
  • L
  • E
  • X

Versão Lean

Lida com seus principais processos facilmente

Excelência técnica
Simplicidade
  • F
  • L
  • E
  • X

Seleção Extended

Otimiza seus processos com tecnologias inovadoras

Excelência técnica
Simplicidade
  • F
  • L
  • E
  • X

Versão Xpert

Controla suas aplicações mais difíceis

Excelência técnica
Simplicidade

Variável

  • Especificações resumidas

    • Process temperature

      max. 400°C (752°F) (diptube)

    • Process pressure absolute / max. overpressure limit

      Any (diptube)

    • Main wetted parts

      Non- contact

please wait Loading alternative products

Seleção rápida

Escolha uma das opções sugeridas
Preço de venda
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

ou

Configuração individual

Continue sua seleção entre todas as opções possíveis
  • Benefícios

    • Highest safety classification for the source supplied (DIN 25426/ISO 2919, typical classification C66646)

    • Reliable measurement due to lightweight container and almost spherical design which provides optimized screening

    • Flexible installation length up to...

  • Campo de aplicação

    Designed to hold the radioactive source during density and interface measurement.

    • Off-position: Radioactive source located in the source container and screens off radiation

    • On-position: Radioactive source with the flexible extension located in the...

Details

  • Measuring principle

    Radiometric Density

  • Characteristic / Application

    Source container with flexible extension element to position the source inside the process vessel (diptube)

    Approximately 87 kg

    Adapter flange: 10 kg

  • Ambient temperature

    -52 °C...+200 °C
    (-61 °F...+392 °F)

  • Process temperature

    max. 400°C (752°F) (diptube)

  • Process pressure absolute

    Any

  • Wetted parts

    Non-contact

  • Hygienic

    Non-contact

  • Specialities

    Control area calculation with Applicator

  • Measuring principle

    Radiometric Limit

  • Characteristic / Application

    Source container with flexible extension element to position the source inside the process vessel (diptube)

    Approximately 87kg

    Adapter flange: 10kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -52 °C...+200 °C
    (-61 °F...+392 °F)

  • Process temperature

    max. 400°C (752°F) (diptube)

  • Process pressure absolute / max. overpressure limit

    Any (diptube)

  • Main wetted parts

    Non- contact

  • Process connection

    Non- contact

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Source container with flexible extension element to position the source inside the process vessel (diptube)

    Approximately 87kg

    Adapter flange: 10kg

  • Specialities

    With flexible extension element

  • Ambient temperature

    -52 °C...+200 °C
    (-61 °F...+392 °F)

  • Process temperature

    max. 400°C (752°F)

  • Process pressure absolute / max. overpressure limit

    Any (diptube)

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Measuring principle

    Radiometric Limit

  • Characteristic / Application

    Source container with flexible extension element to position the source inside the process vessel (diptube)

    Approximately 87kg

    Adapter flange: 10kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -52 °C...+200 °C
    (-61 °F...+392 °F)

  • Process temperature

    max. 400°C (752°F)
    (diptube)

  • Process pressure absolute / max. overpressure limit

    Any (diptube)

  • Main wetted parts

    Non- contact

  • Process connection

    Non- contact

  • Process connection hygienic

    Non- contact

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Source container with flexible extension element to position the source inside the process vessel (diptube)

    Approximately 87kg

    Adapter flange: 10kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -52 °C...+200 °C
    (-61 °F...+392 °F)

  • Process temperature

    max. 400°C (752°F)

  • Process pressure absolute / max. overpressure limit

    Any (diptube)

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

Documentos / Manuais / Software

Acessórios / peças sobressalentes

Nr
Order code
Specification