Especificações resumidas
-
Measurement range
pH 0-14
-
Process temperature
-15°C ... 140°C
(5°F - 284°F) -
Process pressure
max. 13 bar
(188 psi)depends on selected version
Campo de aplicação
Memosens CPS76D is the expert for simultaneous pH and ORP measurement in demanding processes and hygienic applications, offering a better process control and increased quality. The sensor measures reliably at high temperatures and is non-toxic assuring highest safety of your products. Memosens CPS76D is not the latest Memosens generation. To get information on the new Memosens CPS76E sensor with extended functionality, click here.
Process technology and monitoring of processes with:
- Quickly changing pH values
- High proportion of electrode poisons such as H2SChemical processes
Hygienic and sterile applications:
- Fermenters
- Biotechnology
- Life sciences
With ATEX, FM, and CSA approval for application in hazardous areas.
Benefícios
Simultaneous measurement of pH, ORP and rH values (in rH mode) for a better process overview
Additional platinum electrode enables constant monitoring of reference impedance and thus sensor quality
Robust and resistant to poisoning thanks to new acrylamide-free bridge electrolyte and reference with ion trap
Suitable for CIP/SIP and autoclaving
Maximum process safety through non-contact inductive signal transmission
Enables predictive maintenance due to storage of sensor and process-specific data
Reduced operating costs thanks to minimized process downtime and extended sensor lifetime
Vídeos
Seleção Extended
-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade

-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade
-
Produtos especializados
- Desenvolvidos para aplicações exigentes
Excelência técnica
Simplicidade
Variável
Versões FLEX | Excelência técnica | Simplicidade |
---|---|---|
Versão Fundamental Atende suas necessidades básicas de medição |
Excelência técnica
|
Simplicidade
|
Versão Lean Lida com seus principais processos facilmente |
Excelência técnica
|
Simplicidade
|
Seleção Extended Otimiza seus processos com tecnologias inovadoras |
Excelência técnica
|
Simplicidade
|
Versão Xpert Controla suas aplicações mais difíceis |
Excelência técnica
|
Simplicidade
Variável |
-
-
Informação técnica (TI)
Memosens CPS76D Technical Information
Combination of pH and ORP electrode with Memosens technology
EN PT 30/11/201402/05/2012Idioma:
Inglês
Versão:
30/11/2014
Tamanho do arquivo:
420 KB
Nome do arquivo:
TI00506CEN_0214.pdf
-
-
-
Instruções de serviço (BA)
Instruções de operação Memosens CPS16D/76D/96D
Eletrodo pH e ORP combinados com tecnologia Memosens
EN PT 31/01/201822/05/2012Idioma:
Português
Versão:
31/01/2018
Tamanho do arquivo:
627.6 KB
Nome do arquivo:
BA01109CPT_0218.pdf
-
-
-
Instruções de segurança (XA)
Memosens pH/ORP Sicherheitshinweise für elektrische Betriebsmittel im explosionsgefährdeten Bereich Safetyinstructions for electrical apparatus for explosion-hazardous areas Conseils de sécurité pour matériels électriques destinés aux zones explosibles Safety Instructions
Safety instructions for electrical apparatus for explosion-hazardous areas
EN PT 22/02/201604/03/201514/01/201321/10/201001/12/2006Idioma:
Inglês
Versão:
22/02/2016
Tamanho do arquivo:
4.3 MB
Nome do arquivo:
XA00376CA3_1616.pdf
-
-
-
Instruções de segurança (XA)
Memosens pH/ORP Sicherheitshinweise für elektrische Betriebsmittel im explosionsgefährdeten Bereich Safetyinstructions for electrical apparatus for explosion-hazardous areas Conseils de sécurité pour matériels électriques destinés aux zones explosibles Safety Instructions
Safety instructions for electrical apparatus for explosion-hazardous areas
EN PT 11/11/201631/12/201101/04/2009Idioma:
Inglês
Versão:
11/11/2016
Tamanho do arquivo:
3.7 MB
Nome do arquivo:
XA00079CA3_1416.pdf
-
-
-
Instruções de segurança (XA)
Memosens ph/ORP sensors
pH/ORP measurement Supplement to BA01572C, BA01109C Safety instructions for electrical apparatus in explosion-hazardous areas UKEx II 1 G Ex ia IIC T3/T4/T6 Ga UK Ex II 1 G Ex ia IIC T4/T6 Ga
Idioma:
Inglês
Versão:
08/12/2021
Tamanho do arquivo:
435.2 KB
Nome do arquivo:
XA02786CEN_0121-00.pdf
-
-
-
Instruções de segurança (XA)
Memosens pH/ORP sensors
pH and ORP measurement Supplement to: BA01572C, BA01109C Safety instructions for electrical equipment in explosion-hazardous areas EAC Ex 0Ex ia IIC T3/T4/T6 Ga X EAC Ex 0Ex iaIIC T4/T6 Ga X
EN PT 01/03/202218/02/202108/03/2016Idioma:
Inglês
Versão:
01/03/2022
Tamanho do arquivo:
508.1 KB
Nome do arquivo:
XA01437CEN_0322-00.pdf
-
-
-
Brochura de Competências (CP)
pH-Messung in Industrieprozessen
Auswahl- und Engineering-Hilfe für verschiedene Industriebranchen und Applikationen
Idioma:
Alemão
Versão:
25/03/2020
Tamanho do arquivo:
3.3 MB
Nome do arquivo:
CP00010CDE_1520_pH-Auswahlhilfe20.pdf
-
-
-
Brochura de Competências (CP)
pH measurement in industrial processes
Selection and engineering guide for different industries and applications
Idioma:
Inglês
Versão:
24/02/2020
Tamanho do arquivo:
3.3 MB
Nome do arquivo:
CP00010CEN_1520_pH-selection-guide20.pdf
-
-
-
Papel branco
Damit bei der pH-Messung höchste Genauigkeit garantiert ist
Kalibrierung,Justierung und Verifizierung
Idioma:
Alemão
Versão:
07/04/2021
Tamanho do arquivo:
605.2 KB
Nome do arquivo:
WP01154C07DE_01.21_Damit bei der pH-Messung hoechste Genauigkeit garantiert ist.pdf
-
-
-
Papel branco
Ensuring maximum accuracy in pH measurement
Calibration, adjustment and verification
Idioma:
Inglês
Versão:
07/04/2021
Tamanho do arquivo:
600 KB
Nome do arquivo: