Tente buscar por palavras-chaves, código de pedido ou produto ou número de série, por exemplo, "CM442" ou "informações técnicas"
Insira pelo menos 2 caracteres para iniciar a busca.
  • Histórico

Iron analyzer
Liquiline System CA80FE

Liquiline System CA80FE - High-precision process analyzer for iron measurement ©Endress+Hauser
Liquiline System CA80FE - Inside view of the iron analyzer ©Endress+Hauser
Sample collector with level detection for the monitoring of sample transport ©Endress+Hauser

Iron concentration in a liquid can be measured using the colorimetric measuring principle. This video shows what it is about and how this measuring principle works.

Colorimetric system for monitoring of drinking water, mineral water and process water

Liquiline System CA80FE offers precise, regulation-compliant online measurement. It supports you in controlling the iron content of drinking water, mineral water or source water for industrial processes. Like all Liquiline System analyzers, it enables plug & play of up to four Memosens sensors – minimizing the installation effort. Automatic calibration and cleaning and the low reagent consumption reduce operating costs while advanced diagnostics with remote access ensure process safety.

  • Produtos simples

  • Fácil de escolher, instalar e operar

Excelência técnica

Simplicidade

  • Produtos padrão

  • Confiável, robusto e baixa manutenção

Excelência técnica

Simplicidade

  • Produtos com tecnologia de ponta

  • Altamente funcional e prático

Excelência técnica

Simplicidade

  • Produtos especializados

  • Desenvolvidos para aplicações exigentes

Excelência técnica

Simplicidade

Variável

Versões FLEX Excelência técnica Simplicidade
  • F
  • L
  • E
  • X

Versão Fundamental

Atende suas necessidades básicas de medição

Excelência técnica
Simplicidade
  • F
  • L
  • E
  • X

Versão Lean

Lida com seus principais processos facilmente

Excelência técnica
Simplicidade
  • F
  • L
  • E
  • X

Seleção Extended

Otimiza seus processos com tecnologias inovadoras

Excelência técnica
Simplicidade
  • F
  • L
  • E
  • X

Versão Xpert

Controla suas aplicações mais difíceis

Excelência técnica
Simplicidade

Variável

  • Especificações resumidas

    • Measurement range

      0.05 to 2 mg/l Fe
      0.1 to 5 mg/l Fe
      0.1 to 5 mg/l with dilution function to maximum 2.0 to 100 mg/l Fe

    • Process temperature

      4 to 40 °C (39.2 to 104 °F)

    • Process pressure

      At atmospheric pressure, < 0.2 bar

please wait Loading alternative products

Seleção rápida

Escolha uma das opções sugeridas
Preço de venda
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

ou

Configuração individual

Continue sua seleção entre todas as opções possíveis
  • Benefícios

    • Compliance with standard ferrozine method ensures direct comparability to lab measurements

    • Supports predictive maintenance by advanced diagnostics

    • Reduced operating costs through automatic calibration and cleaning as well as low reagent consumption

    • ...

  • Campo de aplicação

    Liquiline System CA80FE monitors:

    • Iron content in drinking water and mineral water

    • Residual iron after precipitation, flocculation and filtration processes

    • Process water containing diluted iron

Características e especificações

Voltar

Details

  • Measuring principle

    Colorimetric

  • Characteristic

    Process analyzer for iron in aqueous solutions
    Comply with standard colorimetric measuring principle, ferrozine method

  • Size

    Housing (open version):

    793 x 530 x 417 mm

    31.22 x 20.87 x 16.42 in


    Housing (closed version):

    793 x 530 x 463 mm

    31.22 x 20.87 x 18.23 in


    Housing with base:

    1723 x 530 x 463 mm

    67.83 x 20.87 x 18.23 in

  • Design

    Open design, cabinet and stand housing
    High-Performance plastic ASA-PC, additional stand coated steel

  • Process temperature

    4 to 40 °C (39.2 to 104 °F)

  • Ambient temperature

    5 to 40 °C (41 to 104 °F)

    Outdoor version: - 20 to 40 °C (-4 to 104 °F)

  • Process pressure

    At atmospheric pressure, < 0.2 bar

  • Sample flow rate

    Min. 5 ml/min (0.17 fl.oz/min)

  • Consistency of the sample

    Suspended solids content
    Turbitity < 50 NTU, aqueous, homogenized

  • Application

    Monitoring of the iron content of potable water, mineral water and source water for industrial processes

  • Power supply

    100 to 120 VAC / 200 to 240 VAC ± 10%
    24 VDC ± 10%
    50 ± 1 or 60 ± 1,2 Hz

  • Output / communication

    2x 0/4 to 20 mA
    Webserver, Modbus, Ethernet/IP, Profibus DP

  • Input

    1 or 2 measuring channel
    1 to 4 digital sensor inputs for sensors with Memosens protocol (optional)

  • Measurement range

    0.05 to 2 mg/l Fe

    0.1 to 5 mg/l Fe

    0.1 to 5 mg/l with dilution function to maximum 2.0 to 100 mg/l Fe

  • Consumables

    Reagents and standard solutions CY80FE for the operation
    Regular maintenance is done with the parts of the maintenance kit CAV800

Documentos / Manuais / Software

Acessórios / peças sobressalentes

Nr
Order code
Specification