Tente buscar por palavras-chaves, código de pedido ou produto ou número de série, por exemplo, "CM442" ou "informações técnicas"
Insira pelo menos 2 caracteres para iniciar a busca.
  • Histórico
Prosonic FDU95 - Ultrasonic measurement

Ultrasonic measurement
Time-of-Flight
Prosonic FDU95

Ultrasonic sensor for level measurement for connection to FMU9x (measuring range up to 45m)

FDU95
Please Wait (spinning wheel)
Carregando preços
Preço temporariamente indisponíveis
Price on request
ativando preços
preço: fornecer informações
from CHF ??.-
Filtrar medição / Tarefa de aplicação
Tarefa de aplicação / medição

Configurar para baixar os desenhos CAD deste produto

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART, Profibus DP)

  • Accuracy

    +/- 2 mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C...80 °C
    or 150 °C,
    (-40 °F...176 °F
    or 302 °F)

  • Process temperature

    -40 °C...80 °C
    or 150 °C,
    (-40 °F...176 °F
    or 302 °F)

  • Process pressure / max. overpressure limit

    0.7 bar...1.5 bar abs
    (10 psi...22 psi)

  • Main wetted parts

    UP (unsaturated polyester)
    Silicon / Al PTFE coated

  • Process connection

    G / NPT 1"

  • Blocking distance

    0.7 m / 80 °C,
    (2.3 ft / 176 °F),
    0.9 m / 150 °C,
    (2.9 ft / 302 °F)

  • Max. measurement distance

    45 m (148 ft)

  • Communication

    Transmitter:
    4...20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

  • Options

    Second 4...20 mA output

  • Components

    Transmitter:
    FMU90, FMU95

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART , Profibus DP)

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C ... 80 °C
    or 150 °C
    (-40 °F ... 176 °F
    or 302 °F)

  • Process temperature

    -40 °C ... 80 °C
    or 150 °C
    (-40 °F ... 176 °F
    or 302 °F)

  • Process pressure / max. overpressure limit

    0.7 bar...1.5 bar abs
    (10 psi...22 psi)

  • Main wetted parts

    UP (unsaturated polyester)
    Silicon / PE foam (80°C / 176°F)
    Silicon / stainless steal (150°C / 302°F))

  • Process connection

    G / NPT 1"

  • Blocking distance

    0.7 m / 80 °C
    (2.3 ft / 176 °F)
    0.9 m / 150 °C
    (2.9 ft / 302 °F)

  • Max. measurement distance

    45 m (148 ft)

  • Communication

    Transmitter:
    4 ... 20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

  • Options

    Second 4...20mA output

  • Components

    Transmitter:
    FMU90