Especificações resumidas
-
Measuring range
0,03 to 2.5 mg/l Cr(VI)
0.2 to 5.0 mg/l Cr(VI)
0.2 to 5.0 mg/l with dilution function to maximum 10 to 250 mg/l Cr(VI) -
Process temperature
4 to 40 °C (39 to 104 °F)
-
Process pressure
At atmospheric pressure, < 0.2 bar absolute
Campo de aplicação
Liquiline System CA80CR offers highly accurate online measurement for optimized chromate removal in industrial wastewater. It supports you in achieving environmentally compliant electroplating and tanning processes. Like all Liquiline System analyzers, CA80CR enables plug & play of up to four Memosens sensors - minimizing the installation effort. Automatic calibration and cleaning plus advanced diagnostics with remote access ensure consistent process safety.
Liquiline System CA80CR supports you in improving the environmental performance of your processes by:
Monitoring and optimizing the cleaning capacity of industrial wastewater treatment plants.
Effluent monitoring in tanneries and electroplating plants.
Monitoring of membrane filtration.
Limit monitoring in drinking water applications.
Benefícios
Standardized colorimetric measuring principle - diphenyle carbazide method - guarantees compliance with discharge regulations.
Reduced operating costs through automatic calibration and cleaning and low reagent consumption.
Simple maintenance: no tools required.
Advanced diagnostics with remote access for increased process safety.
Fast commissioning and plug & play thanks to Memosens technology and user-friendly operation.
Easy upgrade of functionality - even to a complete measuring station - simply by adding modules and connecting Memosens sensors. Reduces installation effort.
Drive connectivity: Liquiline Edge Module CYY7 transfers process data to Netilion, independently of the fieldbus. This allows remote overview and the use of IIoT services. It’s available in new products or as upgrade to installed Liquiline platforms.
Vídeos
-
Chromate concentration in a liquid can be measured using the colorimetric measuring principle. This video shows what it is about and how this measuring principle works.
Seleção Extended
-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade
-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade
-
Produtos especializados
- Desenvolvidos para aplicações exigentes
Excelência técnica
Simplicidade
Variável
| Versões FLEX | Excelência técnica | Simplicidade |
|---|---|---|
Versão Fundamental Atende suas necessidades básicas de medição |
Excelência técnica
|
Simplicidade
|
Versão Lean Lida com seus principais processos facilmente |
Excelência técnica
|
Simplicidade
|
Seleção Extended Otimiza seus processos com tecnologias inovadoras |
Excelência técnica
|
Simplicidade
|
Versão Xpert Controla suas aplicações mais difíceis |
Excelência técnica
|
Simplicidade
Variável |
Predecessor
-
Measuring principle
Colorimetric
-
Characteristic
Analyzer for Chromate (Chrome VI) in aqueous solutions
-
Size
Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in -
Design
Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel -
Process temperature
4 to 40 °C (39 to 104 °F)
-
Ambient temperature
5 to 40 °C (41 to 104 °F)
Outdoor version: - 20 to 40 °C (-4 to 104 °F) -
Process pressure
At atmospheric pressure, < 0.2 bar absolute
-
Sample flow rate
Min. 5 ml/min (0.17 fl.oz/min)
-
Consistency of the sample
Suspended solids content
Turbitity < 50 NTU, aqueous, homogenized -
Specials
Easy upgrade to measuring station with up to four digital Memosens sensors
Automatic calibration and cleaning
User-configurable measuring, cleaning and calibration intervals
Optional cooling module for longer reagent shelf life
2 channel version optional
User-definable measuring ranges
Modular design for easily extensible functionality
Digital communication for remote access -
Application
Limit value monitoring of Chromate in potable water and waste water
Common applications are industrial waste water Monitoring for tanneries and the galvanic industry -
Power supply
100 to 120 VAC / 200 to 240 VAC ± 10%
24 VDC ± 10%
50 ± 1 or 60 ± 1,2 Hz -
Output / communication
2x 0/4 to 20 mA
Modbus RS485/TCP (optional)
Ethernet (optional)
Alarmrelay -
Input
1 or 2 measuring channels
1 to 4 digital sensor inputs for sensors with Memosens protocol (optional) -
Measuring range
0,03 to 2.5 mg/l Cr(VI)
0.2 to 5.0 mg/l Cr(VI)
0.2 to 5.0 mg/l with dilution function to maximum 10 to 250 mg/l Cr(VI) -
Consumables
Reagents and standard solutions CY80CR as well as cleaner CY800 are necessary for the operation
Regular maintenance is done with the parts of the maintenance kit CAV800
-
-
Informações Técnicas (TI)
TI Liquiline System CA80CR
-
Informações Técnicas (TI)
Versão em português - 05/2024New version available in EnglishAnalisador colorimétrico para cromato (Cr(VI))
EN PT 22/05/202429/11/202213/07/202119/02/202009/06/2017Idioma:
Português
Versão:
22/05/2024
Tamanho do arquivo:
4.3 MB
Nome do arquivo:
TI01265CPT_0724-00.pdf
-
-
-
Instruções de Operação (BA)
BA Liquiline System CA80CR
-
Instruções de Operação (BA)
Versão em português - 05/2024New version available in EnglishAnalisador colorimétrico para cromato (Cr(VI))
EN PT 22/05/202429/11/202213/07/202113/01/202009/06/2017Idioma:
Português
Versão:
22/05/2024
Tamanho do arquivo:
6.4 MB
Nome do arquivo:
BA01575CPT_0724-00.pdf
-
-
-
Instruções de Operação (BA)
Memosens
-
Instruções de Operação (BA)
Versão em português - 05/2022New version available in EnglishEntradas do sensor com protocolo Memosens
EN PT 30/05/202228/02/2019Idioma:
Português
Versão:
30/05/2022
Tamanho do arquivo:
3.4 MB
Nome do arquivo:
BA01245CPT_0822-00.pdf
-
-
-
Instruções curtas (KA)
Liquiline System CA80CR
-
Instruções curtas (KA)
Versão em português - 05/2021New version available in EnglishAnalisador colorimétrico para cromato
EN PT 31/05/202119/02/202006/10/201707/04/201701/02/2016Idioma:
Português
Versão:
31/05/2021
Tamanho do arquivo:
3.3 MB
Nome do arquivo:
KA01223CPT_0621.pdf
-
-
-
Instruções de Instalação (EA)
Kits for Analyzer CA80: Engineering parts
-
Instruções de Instalação (EA)
Versão em inglês - 06/2025New version available in EnglishKits for Analyzer CA80: Engineering parts
EN PT 30/06/2025Idioma:
Inglês
Versão:
30/06/2025
Tamanho do arquivo:
2.1 MB
Nome do arquivo:
71223028 Anleitung Kits CA8x Verfahrenstechnik 2022-08.pdf
-
-
-
Instruções de Instalação (EA)
Kit CM44x/CSXxx/CA80XX
-
Instruções de Instalação (EA)
Versão em inglês - 11/2022New version available in EnglishModule 485MB or 485DP
For Ethernet configuration, PROFIBUS DP, Modbus RS485EN PT 28/11/2022Idioma:
Inglês
Versão:
28/11/2022
Tamanho do arquivo:
1.8 MB
Nome do arquivo:
EA01447CEN_0122-00.pdf
-
-
-
Instruções de Instalação (EA)
Kit for analyzer CA8x: Valve
-
Instruções de Instalação (EA)
Versão em inglês - 07/2025New version available in EnglishThis instruction applies to following spare part kit:
71218433 Kit CA8x: ValveEN PT 24/07/202509/05/2025Idioma:
Inglês
Versão:
24/07/2025
Tamanho do arquivo:
2.1 MB
Nome do arquivo:
71231926 Anleitung Kit CA80 Ventil 2025-07.pdf
-
-
-
Instruções de Instalação (EA)
Einbauanleitung/ Installation Instructions Kit Module/Modules
-
Instruções de Instalação (EA)
Versão em inglês - 07/2014New version available in EnglishFür erweiterte Funktionalität
For extended functionalityEN PT 07/07/201425/03/201331/12/2011Idioma:
Inglês
Versão:
07/07/2014
Tamanho do arquivo:
2.4 MB
Nome do arquivo:
EA00008CA2_0314.pdf
-
-
-
Instruções de Instalação (EA)
Kits for Analyzer CA8x: Housing parts
-
Instruções de Instalação (EA)
Versão em inglês - 03/2025New version available in EnglishInstallation instruction: Kits for Analyzer CA8x: Housing parts
EN PT 03/03/2025Idioma:
Inglês
Versão:
03/03/2025
Tamanho do arquivo:
957.4 KB
Nome do arquivo:
71223031 Anleitung Kits CA8x Gehaeuseteile 2022-06.pdf
-
-
-
Instruções de Instalação (EA)
EA Liquiline System analyzer CA80COD/TP
-
Instruções de Instalação (EA)
Versão em inglês - 12/2025New version available in EnglishCarrier plate components
EN PT 04/12/202516/07/2025Idioma:
Inglês
Versão:
04/12/2025
Tamanho do arquivo:
5.4 MB
Nome do arquivo:
EA01677CEN_0225-00.pdf
-
Escolha uma das opções sugeridas
-
-- selected coding-- selected label99.999,00<%label%>
-
Procurando mais opções? Use o configurador individual para continuar.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Procurando mais opções? Use o configurador individual para continuar.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- Diagramas CAD Diagramas CAD
- Diagramas CAD
-
Preço por peça
-
<%range%><%price%>
-
- Acessórios opcionais
Configuração individual
Geralmente são fornecidos juntos
Acessórios