Especificações resumidas
-
Max. measurement error
Volume flow:
±3% o.r. for DN15
±2% o.r. for DN25 to DN200
±2% o.r. above DN200 -
Measuring range
0.3 to 10 m/s (1 to 33 ft/s)
-
Medium temperature range
DN15 to 65
-40 to +100°C (-40 +212 °F)
-40 to +150°C (-40 +302 °F) option
DN50 to 4000
-40 to +80°C (-40 +276 °F)
-40 to +170°C (-40 +338 °F) option -
Max. process pressure
N/A
-
Wetted materials
Clamp on system:
Sensor holder 1.4308/CF-8
Sensor housing 1.4301/304
Strapping bands 1.4301/304
Campo de aplicação
The Prosonic Flow P clamp-on sensor was specially designed for the process industry. Combined with the Prosonic Flow 93 transmitter with touch control, four-line display and extended functionality, Prosonic Flow 93P offers high accuracy in standard applications.
The measuring principle is independent of pressure, density, temperature, conductivity and viscosity
Ideal clamp-on device for applications with chemicals, solvents, liquid hydrocarbons, acids and alkalis.
Device properties:
Medium temperature: –40 to 170 °C (–40 to 338 °F)
Wide nominal diameter range: DN 15 to 4000 (1/2 to 160")
Process piping unaffected by meter installation
Aluminium transmitter housing
4‐line backlit display with touch control
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus
Benefícios
Automatic frequency scan for maximum measuring performance
Increased safety for chemical and petrochemical industry – international hazardous area approvals
Long-term stable signal - maintenance-free permanent mounting from outside with coupling pads
Process transparency – diagnostic capability
Highest performance – extended functionality and diagnostics
Flexible data transfer options – numerous communication types
Automatic recovery of data for servicing
Vídeos
-
The Ultrasonic Flow Measuring Principle
Seleção Extended
-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade

-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade
-
Produtos especializados
- Desenvolvidos para aplicações exigentes
Excelência técnica
Simplicidade
Variável
Versões FLEX | Excelência técnica | Simplicidade |
---|---|---|
Versão Fundamental Atende suas necessidades básicas de medição |
Excelência técnica
|
Simplicidade
|
Versão Lean Lida com seus principais processos facilmente |
Excelência técnica
|
Simplicidade
|
Seleção Extended Otimiza seus processos com tecnologias inovadoras |
Excelência técnica
|
Simplicidade
|
Versão Xpert Controla suas aplicações mais difíceis |
Excelência técnica
|
Simplicidade
Variável |
Predecessor
-
Measuring principle
Ultrasonic flow
-
Product headline
Flowmeter for hazardous area installations with a wide range of analog and digital outputs.
Automatic frequency scan for maximum measuring performance.
Ideal clamp-on device for applications with chemicals, solvents, liquid hydrocarbons, acids, alkalis. -
Sensor features
Increased safety for chemical and petrochemical industry – international hazardous area approvals. Long-term stable signal – maintenance-free permanent mounting from outside with coupling pads. Process transparency – diagnostic capability.
Medium temperature: –40 to 170 °C (–40 to 338 °F). Wide nominal diameter range: DN 15 to 4000 (½ to 160"). Process piping unaffected by meter installation. -
Transmitter features
Highest performance – extended functionality and diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing.
Aluminium transmitter housing. 4‐line backlit display with touch control. HART, PROFIBUS PA/DP, FOUNDATION Fieldbus. -
Nominal diameter range
Single channel, 1 or 2 paths : DN15 to 4000 (1/2 to 160")
Dual channel, 1 or 2 paths : DN15 to 4000 (1/2 to 160") -
Wetted materials
Clamp on system:
Sensor holder 1.4308/CF-8
Sensor housing 1.4301/304
Strapping bands 1.4301/304 -
Measured variables
Volume flow channel 1&2, average volume flow, volume flow difference, sound velocity, flow velocity, totalizer
-
Max. measurement error
Volume flow:
±3% o.r. for DN15
±2% o.r. for DN25 to DN200
±2% o.r. above DN200 -
Measuring range
0.3 to 10 m/s (1 to 33 ft/s)
-
Max. process pressure
N/A
-
Medium temperature range
DN15 to 65
-40 to +100°C (-40 +212 °F)
-40 to +150°C (-40 +302 °F) option
DN50 to 4000
-40 to +80°C (-40 +276 °F)
-40 to +170°C (-40 +338 °F) option -
Ambient temperature range
-20 to +60 °C (-4 to +140 °F)
-40 to +60 °C (-40 to +140 °F) optional -
Sensor housing material
N/A
-
Transmitter housing material
Wall-mounted housing: powder-coated die-cast aluminum
-
Degree of protection
IP67, type 4X for transmitter
IP68 type 6P for sensors. Transmitter: IP67, type 4X enclosure -
Display/Operation
4 lines backlit display with three optical keys
-
Outputs
1x 4-20 mA HART
1x Pulse/frequency/switch output (passive) -
Inputs
N/A
-
Digital communication
HART
PROFIBUS PA
Profibus DP
FOUNDATION Fieldbus -
Power supply
85 to 260 V AC
20 to 55 V AC
16 to 62V DC -
Hazardous area approvals
ATEX, FM/CSA, NEPSI, JPN
-
Other approvals and certificates
Flowmeter verification for DN15, 25, 40, 50 & 100 only
Marine certificate
EAC marking -
Product safety
EAC marking
-
Metrological approvals and certificates
Flowmeter verification for DN15, 25, 40, 50 & 100 only
-
Marine approvals and certificates
Marine certificate
Configurar para baixar os desenhos CAD deste produto
Escolha uma das opções sugeridas
-
-- selected coding-- selected label99.999,00<%label%>
-
Procurando mais opções? Use o configurador individual para continuar.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Procurando mais opções? Use o configurador individual para continuar.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
-
Preço por peça
-
<%range%><%price%>
-
- Acessórios opcionais
Configuração individual
Geralmente são fornecidos juntos
Acessórios