Cubemass DCI
Coriolis flowmeter
Compact sensor for smallest quantities with seamless system integration
Cubemass DCI is the proven sensor for the measurement of smallest flow rates in skids, test rigs and industrial robotics, e.g. in applications like lacquering or surface finishing. Neither high pressure nor alternating flow conditions compromise its accuracy. Equipment manufacturers value Cubemass CDI as compact Coriolis sensor with various communication possibilities.
-
Benefícios
Measuring accurately smallest quantities of liquids and gases
Space-saving installation – compact single-tube design
Fewer process measuring points – multivariable measurement (flow, density, temperature)
Suitable for skids – lightweight sensor
High...
-
Campo de aplicação
Measuring principle operates independently of physical fluid properties such as viscosity or density
Measuring accurately smallest quantities of liquids and gases
Device properties
Nominal diameter: DN 1 to 6 (1/24 to 1/4")
Process pressure up to 400...
Documentos / Manuais / Software
-
Cubemass DCI
Technical Information
Coriolis flowmeter
The ultra-compact sensor for smallest quantities with seamless system
integrationTechnical Information (TI) -
Cubemass DCI
MODBUS RS485
Operating Instructions
Coriolis flowmeter
Operating Instruction (BA) -
Cubemass DCI
HART
Operating Instructions
Coriolis flowmeter
Operating Instruction (BA) -
Cubemass DCI
MODBUS RS485
Description of Device Functions
Coriolis flowmeter
Device Parameter (GP) -
Cubemass DCI
HART
Description of Device Functions
Coriolis flowmeter
Device Parameter (GP) -
Cubemass DCI
Brief Operating Instructions
Coriolis mass flow measuring system
Short Instruction (KA)11/09Inglês -
Replacing Sensor parts remote version
Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, Cubemass 8CN,
CNGmass 8DFMounting Instruction (EA) -
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
Mounting Instruction (EA) -
Repair kit cover remote version
Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, CNGmass DCI,
Cubemass DCI, Prosonic Flow 92 F, t-mass 65Mounting Instruction (EA) -
I/O-board, subprint, screening sheed
Installation Instructions
Promag 50, 51, 53, 55, Promass 40, 80, 83, 84, 8ME, Cubemass DCI 8CN,
CNGmass DCI 8DF, Prosonic Flow 90, 93, t-mass 65Mounting Instruction (EA) -
Replacing cover and O-ring
Installation Instructions
romag 10, 23, 50, 51, 53, 55, 400, 800, Promass 40, 80, 83, 84, 8ME,
CNGmass 8FF, LPGmass 8FE, Cubemass 8CM, Prosonic Flow 90, 91,9
2, 93, t-mass 65, Prowirl 72, 73Mounting Instruction (EA) -
Replacing interface parts
Installation Instructions
Promass 40, 80, 83, 84, Cubemass 8CN, CNGmass 8DF
Mounting Instruction (EA) -
Replacing amplifier board for harsh environment (HE)
Installation Instructions
Promag 50, 53, 55, Promass 80, 83, 84, Cubemass DCI 8CN, CNGmass DCI 8DF
Mounting Instruction (EA) -
Replacing amplifier board
Installation Instructions
Promag 50, 51, 53, 55, Promass 40, 80, 83, 84, Cubemass DCI 8CN, CNGmass
DCI 8DF, Prosonic Flow 90, 93, t-mass 65Mounting Instruction (EA) -
Replacing I/O-board and subprints for harsh environment (HE)
Installation Instructions
Promag 50, 53, 55, Promass 80, 83, 84, CNGmass 8DF, Cubemass 8CN
Mounting Instruction (EA) -
Replacing S-DAT
Installation Instructions
Promag 23, 50, 51, 53, 55, Promass 40, 80, 83, 84, 8ME, 8WF, Cubemass
DCI 8CN, CNGmass DCI 8DF, t-mass 65Mounting Instruction (EA) -
Replacing connecting cable
Installation Instructions
Promass 60, 63, 64, 80, 83, 84
Mounting Instruction (EA) -
Replacing transmitter parts
Installation Instructions
Promag 50, 51, 53, 55, Promass 40, 80, 83, 84, Prosonic Flow 90, 93,
t-mass 65, Cubemass 8CN, CNGmass 8DFMounting Instruction (EA) -
Replacing T-DAT
Installation Instructions
Promag 23, 53, 55, Promass 83, 84, 8WF, 8ME, Cubemass DCI 8CN, CNGmass
DCI 8DF, Prosonic Flow 91, 93, t-mass 65Mounting Instruction (EA) -
Replacing power supply for harsh environment (HE)
Installation Instructions
Promag 50, 53, 55, Promass 40, 80, 83, 84, CNGmass DCI, Cubemass DCI,
Prosonic Flow 93 PMounting Instruction (EA) -
Replacing Power supply and display
Installation Instructions
Promag 50, 51, 53, 55, Promass 40, 80, 83, 84, 8ME, Cubemass DCI 8CN,
CNGmass DCI 8DF, Prosonic Flow 90, 93, t-mass 65Mounting Instruction (EA) -
Cubemass DCI
NEPSI Zone 1, Zone 21
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Cubemass DCI
NEC/CEC
Division 1
Ex-documentation
Ex documentation for the operating instruction:
BA00139D, BA00141DEx Safety Instructions (XA) -
Cubemass DCI
ATEX II2GD
IECEx Zone 1, 21
Ex documentation
Ex-Dokumentation zur Betriebsanleitung:
Ex documentation for the operating instruction:
Documentation Ex relative à la mise en service:
BA00139D, BA00141DEx Safety Instructions (XA) -
Change of Directives
Special Documentation
Change of Directives
Special Documentation (SD) -
Przepływomierze Coriolisa PAR_01_2010
Cubemass - Najmniejszy masowy przepływomierz
Coriolisa od Endress+HauserPublications (PU)03/12Polonês -
Flow measurement in utilities - for the US Market
Energy management in your hands - customized solutions for
compressed air, gas, steam and waterCompetence Brochure (CP)12/10Inglês -
Modern measurement on filling machines
Filling, cleaning and sterilization
Competence Brochure (CP)07/10Inglês -
A 15% cost saving in sludge dewatering by reducing flocculant dosage.
Dewatering of sludge is a process aimed at reducing its volume by
removing as much water as possible. Frequently this is done
mechanically, where the sediment is subjected to a so-called
conditioning
process; this involves changing the structure and properties of the
sediment, weakening the forces binding water to the surface of
particles.
A commonly used method of conditioning is a chemical method and
consists of adding electrolytes to the sludge, such as aluminum sulfate,
ferric sulfate or ferric chloride, or polyelectrolytes based on organic
polymers.Case Studies (CS)06/11Inglês -
Cubemass
Código do Produto: 8CN-
Número declaração: EC_00234_02.16EU DeclarationAlemão , Inglês , fr -
Cubemass
Código do Produto: 8CN-
Número declaração: EC_00235_01.16EU DeclarationAlemão , Inglês , fr -
Cubemass
Código do Produto: 8CN-
Região: Europe (ATEX)
Agente Certificador: EXAM (DMT, BVS)
Proteção: Ex tb, Ex db eb iaExplosion ProtectionAlemão , Inglês -
CNGmass, Promass 83, Promass 80, Promass 84, Cubemass, Promass 40
Código do Produto: 83F-, 83E-, 83H-, 83I-, 83P-, 83M-, 83S-, 83A-, 83O-, 83X-, 80F-, 80E-, 80H-, 80I-, 80M-, 84F-, 80P-, 80S-, 80A-, 84M-, 84A-, 84O-, 40E-, 8DF-, 8CN-, 84X-
Região: Brazil
Agente Certificador: TÜV
Categoria: zone 1, zone 0, zone 21
Proteção: Ex d e [ia], Ex d [ia], Ex ia, Ex tb, Ex d [ia Ga], Ex d e [ia Ga], Ex tb [ia Da], Ex ia tbExplosion ProtectionPortuguês -
Cubemass
Código do Produto: 8CN-
Região: Canada, USA
Agente Certificador: CSAExplosion ProtectionInglês -
Cubemass
Código do Produto: 8CN-
Região: International (IECEx)
Agente Certificador: EXAM (DMT, BVS)
Proteção: Ex tb, Ex tb [ia Da], Ex db eb iaExplosion ProtectionInglês -
CNGmass, Cubemass, Promass 40, Promass 80, Promass 83, Promass 84
Código do Produto: 83M-, 83O-, 83P-, 83S-, 83X-, 84A-, 84F-, 84M-, 84O-, 84X-, 8CM-, 8CN-, 8DF-, 8FF-, 83I-, 83H-, 83F-, 83E-, 83A-, 80S-, 80P-, 80M-, 80I-, 80H-, 80F-, 80E-, 80A-, 40E-
Região: India
Agente Certificador: CC(O)E
Categoria: zone 1Explosion ProtectionInglês -
CNGmass, Cubemass, Promass 40, Promass 80, Promass 83, Promass 84
Código do Produto: 83F-, 83E-, 83A-, 83S-, 83I-, 83P-, 83H-, 83X-, 83O-, 80F-, 80E-, 80S-, 80P-, 80I-, 80A-, 8FF-, 8DF-, 8CN-, 8CM-, 84X-, 84O-, 84F-, 84A-, 80H-, 40E-
Região: South Africa
Agente Certificador: SABS
Categoria: zone 21, zone 1, zone 0,1
Proteção: Ex ia tb, Ex tb [ia Da], Ex d e [ia Ga], Ex d [ia Ga], Ex tb, Ex ia, Ex d e [ia], Ex d [ia]Explosion ProtectionInglês -
CNGmass, Cubemass, Promass 40, Promass 80, Promass 83, Promass 84
Código do Produto: 8DF-, 8CN-, 84X-, 84O-, 84M-, 84F-, 84A-, 83X-, 83S-, 83P-, 83O-, 83M-, 83I-, 83H-, 83F-, 83E-, 83A-, 80S-, 80P-, 80M-, 80I-, 80H-, 80F-, 80E-, 80A-, 40E-
Região: India
Agente Certificador: CC(O)E
Categoria: zone 1, zone 2Explosion ProtectionInglês -
Cubemass
Código do Produto: 8CN-
Região: USA
Agente Certificador: FM
Categoria: I,II,III/1/A,B,C,D,E,F,G/T
Proteção: XP/IS/DIPExplosion ProtectionInglês -
Cubemass, Promass 83, Promass 80, Promass 84, Promass 40
Código do Produto: 8CN-, 83F-, 83E-, 83H-, 83I-, 83P-, 83S-, 83A-, 83O-, 83X-, 80F-, 80E-, 80H-, 80I-, 84F-, 80S-, 80A-, 84A-, 84O-, 40E-, 84X-
Região: China
Agente Certificador: NEPSI
Categoria: zone 1
Proteção: Ex d e [ia Ga], Ex d [ia Ga], Ex tD A21 IP6X, Ex ia, Ex d e [ia], Ex d [ia]Explosion ProtectionInglês
Acessórios / peças sobressalentes
-
-
Nr F Order code 50098557
-
Nr F Order code 71039431
Kit p.s.b.40/8X 220V REx000 HE
HE = harsh environment 220V = 85-260VAC
-
Nr F Order code 50098558
-
Nr F Order code 71039432
Kit p.s.b.8X 220V REx120 HE Ex
HE = harsh environment 220V = 85-260VAC
-
Nr F Order code 50098565
-
Nr F Order code 71039434
Kit p.s.b.8X 24V REx000 HE
HE = harsh environment 24V = 20-55VAC / 16-62VDC
-
Nr F Order code 50098566
-
Nr F Order code 71039436
Kit P.s.b. 8X 24V REx120 HE Ex
HE = harsh environment 24V = 20-55VAC / 16-62VDC
-
-
-
Nr 7 Order code 50094002
Kit 10 fuses 250 VAC T800 MA
-
Nr 7 Order code 50094003
Kit 10 fuses 250 VAC T 2A00
-
-
-
Nr B Order code 71106645
Kit amplifier Cubemass DCI WEA Ex
WEA= Language DE+EN+FR+IT+ES+PT+NL
-
Nr B Order code 71106647
Kit amplifier Cubemass DCI WEA HE Ex
WEA= Language DE+EN+FR+IT+ES+PT+NL HE = harsh environment
-
Nr B Order code 71106649
Kit amplifier Cubemass DCI EES Ex
EES= Language SV+FI+NO+RU+PL+CS+EN
-
Nr B Order code 71106652
Kit amplifier Cubemass DCI EES HE Ex
EES= Language SV+FI+NO+RU+PL+CS+EN HE = harsh environment
-
Nr B Order code 71106653
-
Nr B Order code 71106655
Kit amplifier Cubemass DCI SEA HE Ex
SEA= Language JA+ID+EN HE = harsh environment
-
Nr B Order code 71106656
-
Nr B Order code 71106657
Kit amplifier Cubemass DCI CN HE Ex
CN= Language ZH + EN HE = harsh environment
-
-
-
Nr C Order code 50098302
-
Nr C Order code 71039479
Kit I/O Iout passive/Frequency HE Exi
50/53/8X HE = harsh environment
-
Nr C Order code 50098303
-
Nr C Order code 71039478
Kit I/O Iout active/Frequency HE Exi
50/53/8X HE = harsh environment
-
-
-
Nr D Order code 71021743
-
Nr D Order code 71039485
Kit I/O Modb.RS485+Stat.In 2Interf.HE EX
53/83/84/8CN/8DF HE = Harsh environment
-
Nr D Order code 50096833
-
Nr D Order code 71039477
Kit I/O current out 3 Interface HE EX
53/55/8X HE = harsh environment
-
-
-
Nr 2 Order code 50096834
-
Nr 2 Order code 71039487
-
-
-
Nr 5 Order code 50096836
-
Nr 5 Order code 50096836
-
Nr 5 Order code 71039491
Kit Sub PCB Relay out HE
53/55/83/84/8CN/8DF HE = Harsh environment
-
Nr 5 Order code 71039491
Kit Sub PCB Relay out HE
53/55/83/84/8CN/8DF HE = Harsh environment
-
-
-
Nr 4 Order code 50096837
-
Nr 4 Order code 71039492
-
-
-
Nr 31 Order code 50108692
Kit Sub PCB 84/8CN/8DF frequency out
-
Nr 31 Order code 50108692
Kit Sub PCB 84/8CN/8DF frequency out
-
Nr 31 Order code 71039490
-
Nr 31 Order code 71039490
-
-
-
Nr J Order code 50096755
-
-
-
Nr E Order code 50096754
-
-
-
Nr G Order code 50094016
Kit Bus/connec.b.5X/40/8X/65 field hous.
-
-
-
Nr 21 Order code 50094017
Kit Bus PCB/PCB carr.5X/8X/9X/65 wall
-
-
-
Nr 18 Order code 50094014
Kit connec. board In/Output Wall encl
-
-
-
Nr 19 Order code 50098637
Kit connec. board PMASS8X wall enclo
-
Nr 19 Order code 71039493
-
-
-
Nr A Order code 50098705
-
Nr A Order code 71039494
Kit connection board 8X FS HE
Sensor: A/I/M/F/H/E/S/P/O/X HE = harsh environment
-
Nr A Order code 50098706
-
Nr A Order code 71039495
Kit connection board 8X FS HE EX
Sensor: A/I/M/F/H/E/S/O/X, HE = harsh environment
-
-
-
Nr 29 Order code 50108139
Kit Termin.Block field hous. 5X/8X/40/65
-
-
-
Nr 30 Order code 50108140
Kit Termin.Block Wall encl. 5X/8X/9X/65
-
-
-
Nr 1 Order code 50094004
Kit T-DAT Transmitter Data Chip
-
-
-
Nr S Order code 71003953
Kit S-Dat Promass 84/8CN/8DF programmed
Serialnumber is forceful required
-
-
-
Nr 8 Order code 50094026
Kit Cover 5X/40/8X/65 with window
-
-
-
Nr 32 Order code 50094027
Kit Cover 5X/40/8X/93/65 with window Exd
-
-
-
Nr 10 Order code 50094038
-
Nr 10 Order code 50094038
-
Nr 10 Order code 50094038
-
Nr 10 Order code 71247838
Repair kit cover, remote version
Usage: 10/5X/8X/8DF/8CN/92F/65/400/800 acc. service info SI01351D-1/06 Consists of: Cover Rep.kit for G14, O-Ring 110.00 x 4.50 HNBR, Grease
-
Nr 10 Order code 50094038
-
-
-
Nr 34 Order code 50094039
Kit Cover 5X/40/8X/93/65 Conn.termi.Exe
-
-
-
Nr 35 Order code 50094040
Kit Cover 5X/40/8X/93/65 Conn.termi.Exd
-
-
-
Nr 15 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 15 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 15 Order code 50096840
Kit 10 cable glands M20x1,5
-
Nr 15 Order code 50096840
Kit 10 cable glands M20x1,5
-
Nr 15 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 15 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 15 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
Nr 15 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
-
-
Nr 12 Order code 50096839
Kit Circuit board cpl field/SS-housing
-
-
-
Nr 14 Order code 50099102
Kit Bushing to field/SS-housing
-
-
-
Nr 36 Order code 71008445
Kit Terminal protective Cover Ex
-
-
-
Nr 13 Order code 50096841
Kit Ground terminal / Cover clamp
-
-
-
Order code 50098636
Kit 2 Screening sheet wall enclo.
-
Order code 50096838
Kit 2 Screening sheet field housing
-
-
-
Nr 20 Order code 50094041
Kit Seal cover to Wall enclosure
-
-
-
Nr 11 Order code 50094050
Kit 10 Seal cover to field housing
-
-
-
Nr 25 Order code 50098703
-
-
-
Nr 26 Order code 50103152
Kit Part Promass E/F-HT/C/F-DCI/X FS
-
-
-
Nr 24 Order code 50098704
-
-
-
Nr 28 Order code 50093554
Kit cable Promass remote version 10m
-
Nr 28 Order code 50093573
Kit cable Promass remote version 20m
-
Nr 28 Order code 50098567
Kit cable PROMASS remote version 10m Ex
-
Nr 28 Order code 50098568
Kit cable PROMASS remote version 20m Ex
-
-
-
Order code 71123816
Mounting plate Cubemass packed
Universal mounting plate for fixing the flowmeter to various surfaces, such as walls, switchboards etc.
-
Order code DK8WM-
Transmitter 80/83/84, mounting set
-
Order code DK8CS-
Cubemass, mounting kit
Adapters for different process connection standards. To be connected to the Cajon couplings.
-
Order code FXA193-
Serviceinterface FXA193
The service interface connects the service port of Proline and ToF devices with the serial interface RS 232C (9 pin.) of a personal computer. Contents of delivery: - Serviceinterface with RS 232C connection cable (9 pin.) - FXA "USB" cable, the additional power supply for FXA193 from USB-port of the PC.
-
-
Successor