Proline Prosonic Flow 93C
Ultrasonic flowmeter

Picture of ultrasonic flowmeter Proline Prosonic Flow 93C for water and wastewater applications ©Endress+Hauser

Proline Prosonic Flow 93C for water and wastewater applications

The Ultrasonic Flow Measuring Principle

Accurate flowmeter for large pipes up to DN 2000 and with a wide range of outputs

The Prosonic flow 93C Inline is designed for water and waste water applications. The measuring system consists of a combination of a Prosonic Flow 93 transmitter in wall mounting housing and an optimized version of the Prosonic Flow W insertion sensor. By the use of Prosonic Flow 93C Inline, you profit from the fundamental, high accuracy of an ultrasonic flow measuring system and the possibility of a traceable calibration.

  • Benefícios

    • No production losses – removal or replacement of sensor elements without process shutdown

    • No additional pressure loss – full bore design

    • Process transparency – diagnostic capability

    • Highest performance – extended functionality and diagnostics

    • Flexible data...

  • Campo de aplicação

    • The measuring principle is independent of pressure, density, temperature, conductivity and viscosity

    • Inline flow measurement of process water saltwater, demineralized water, drinking water and wastewater

    Device properties:

    • Internationally recognized...

Características e especificações

Voltar

Details

  • Measuring principle

    Ultrasonic flow

  • Product headline

    The accurate flowmeter for large pipes up to DN 2000 and with a wide range of analog and digital outputs. Inline flow measurement of process water saltwater, deminerialized water, drinking water and wastewater.

  • Sensor features

    No production losses – removal or replacement of sensor elements without process shutdown. No additional pressure loss – full bore design. Process transparency – diagnostic capability. Internationally recognized drinking water approvals. Nominal diameter: DN 300 to 2000 (12 to 80").

  • Transmitter features

    Highest performance – extended functionality and diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. Aluminium transmitter housing. 4‐line backlit display with touch control.

  • Nominal diameter range

    DN 300 to 2'000 (12" to AWWA 78")

  • Wetted materials

    Sensor housing: 1.4404/DN 17440 (316L/AISI)
    Weld-in parts: 1.4404/DN 17440 (316L/AISI)
    Measuring pipe: ST 37.2 (carbon steel)

  • Measured variables

    Volume flow channel 1 or 2, sound velocity, flow velocity, average volume flow, average sound velocity, average flow velocity, totalizer

  • Max. measurement error

    +/-0.5 %

  • Measuring range

    0 to 47'000 m3/h 0 to 176 Mgal/min

  • Max. process pressure

    PN 16, Cl. 150

  • Medium temperature range

    -20 to +60°C (-4 to 140°F)

  • Ambient temperature range

    Transmitter:
    –20 to +60 °C (–4 to +140 °F)
    Sensor:
    –20 to +80 °C (–4 to +176 °F)

  • Transmitter housing material

    Wall-mounted housing: powder-coated die-cast aluminum

  • Degree of protection

    Transmitter
    IP 67 (NEMA 4X)
    Sensor
    IP 68 (NEMA 6P)

  • Display/Operation

    4 lines backlit display with three optical keys

  • Outputs

    1x 4-20 mA HART
    1x Pulse/frequency/switch output (passive)

  • Inputs

    N/A

  • Digital communication

    HART, PROFIBUS PA, PROFIBUS DP, FOUNDATION Fieldbus

  • Power supply

    AC 85 to 260 V
    AC 20 to 55 V
    DC 16 to 62V

  • Hazardous area approvals

    FM
    CSA

  • Product safety

    CE, C-Tick

Documentos / Manuais / Software

Acessórios / peças sobressalentes

Nr
Order code
Specification