Proline Promass A 300 / 8A3B
This product is not available in this market.
Documentos / Manuais / Software
-
Proline Promass A 300
Technical Information
Coriolis flowmeter
The single‐tube flowmeter for smallest flow quantities with a compact,
easily accessible transmitterTechnical Information (TI) -
Proline Promass A 300
EtherNet/IP
Operating Instructions
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass A 300
FOUNDATION Fieldbus
Operating Instructions
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass A 300
HART
Operating Instructions
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass A 300
Modbus RS485
Operating Instructions
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass A 300
PROFIBUS PA
Operating Instructions
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass A 300
PROFINET
Operating Instructions
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass 300
PROFIBUS PA
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 300
FOUNDATION Fieldbus
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 300
PROFINET
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 300
Modbus RS485
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 300
HART
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 300
EtherNet/IP
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline 300
PROFIBUS PA
Resumo das instruções de operação
Transmissor com sensor Coriolis
Short Instruction (KA)11/18Inglês -
Proline 300
HART
Resumo das instruções de operação
Transmissor com sensor Coriolis
Short Instruction (KA)08/18Inglês -
Proline 300
PROFINET
Resumo das instruções de operação
Transmissor com sensor Coriolis
Short Instruction (KA)08/18Inglês -
Proline 300
Modbus RS485
Resumo das instruções de operação
Transmissor com sensor Coriolis
Short Instruction (KA)08/18Inglês -
Proline 300
FOUNDATION Fieldbus
Resumo das instruções de operação
Transmissor com sensor Coriolis
Short Instruction (KA)08/18Inglês -
Proline 300
EtherNet/IP
Resumo das instruções de operação
Transmissor com sensor Coriolis
Short Instruction (KA)08/18Inglês -
Proline 300
Modbus RS485
Resumo das instruções de operação
Parte 2 de 2
TransmissorShort Instruction (KA)08/16Inglês -
Proline 300
HART
Resumo das instruções de operação
Parte 2 de 2
TransmissorShort Instruction (KA)08/16Inglês -
Proline Promass
Resumo das instruções de operação
Proline Promass
Parte 1 de 2
Sensor CoriolisShort Instruction (KA)04/17Inglês -
Medidor de vazão
Proline 300
Resumo das instruções de operação
Transmissor com
sensor eletromagnéticoShort Instruction (KA)02/19Inglês -
Proline Promass A
Resumo das instruções de operação
Proline Promass A
Sensor CoriolisShort Instruction (KA)02/17Inglês -
Protective Cover connection compartment
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital
Mounting Instruction (EA) -
Alteration with correspondent I/O hardware for HART, Modbus
Installation Instructions
Promag, Promass 300, 500, 500-digital
Mounting Instruction (EA) -
Weather Protection
Installation Instructions
Promag, Promass 300, 500, Prosonic Flow 300
Mounting Instruction (EA) -
Alteration with display and operating module DKX001
Installation Instructions
Promag, Promass, Prosonic Flow 300
Mounting Instruction (EA) -
Kit wireless antenna for extended range
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital
Mounting Instruction (EA) -
Replacing the electronics
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital
Mounting Instruction (EA) -
Replacing ISEM electronics module, ISEM extender, ribbon cable
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital
Mounting Instruction (EA) -
Replacing the transmitter Promag, Promass 300
Installation Instruction
Promag 300, Promass 300Mounting Instruction (EA) -
Cover for remote display module, O-ring for cover
Installation Instructions
Promag, Promass, Prosonic Flow 300
Mounting Instruction (EA) -
Display module
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
DKX001–Mounting Instruction (EA) -
Conversion Kit for Promag, Promass 300 Compact Version to Promag,
Promass 500 Remote Version
Installation Instructions
Promag, Promass 300, 500
Mounting Instruction (EA) -
Replacing cover, O-ring cover, Interface gasket
Installation Instructions
Promag, Promass 300, 500, Prosonic Flow 300
Mounting Instruction (EA) -
Replacing Spare Parts
Installation Instructions
Promag, Promass 100, CNGmass, LNGmass, LPGmass, Promag 400 Index C,
Promag, Promass 300, 500, 500-digital, Prosonic Flow E 100, Pros
onic Flow E Heat, Prosonic Flow 300, 500-digialMounting Instruction (EA) -
Replacing cover, O-ring, seal housing for transmitter wall mounting and
seal housing for the sensor side
Installation Instructions
Promag, Promass 500, 500-digital, Prosonic Flow 500-digital
Mounting Instruction (EA) -
Activating application packages, switching the I/O function, upgrading
with additional I/O hardware
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital
Mounting Instruction (EA) -
Alteration to Display module, to Display module with WirelessHART or
Display module with WLAN
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital
Mounting Instruction (EA) -
Terminal connection
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital
Mounting Instruction (EA) -
Replacing the S-DAT
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalMounting Instruction (EA) -
Proline Promass 300
NEPSI:
Zone 0/1
Zone 1
Zone 21
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 300
INMETRO:
Zona 2
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Promass 300
CSA:
Class I, Zone 1
Zone 21
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 300
NEPSI:
Zone 2
Ex nA version
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 300
JPN:
特別危険箇所/第 1 類危険箇所、第 1 類危険箇所、ゾーン 21
Ex d バージョン
安全上の注意事項
危険場所に関する関連資料
Ex Safety Instructions (XA) -
Proline Promass 300
INMETRO:
Zona 0/1
Zona 1
Zona 21
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Promass 300
ATEX:
II2G, II1/2G
II2D
IECEx:
Zone 1, Zone 0/1
Zone 21
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Promass 300
CSA:
Class I, Zone 2
Class I, Division 2
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 300
Class I, II, III Division1 for XP
(Ex d Flameproofed version)
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 300
ATEX:
II3G
IECEx:
Zone 2
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Promass 300
HART
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Heating jacket
For Promass A Coriolis flowmeters
Special Documentation
Heating jacket
For Promass A Coriolis flowmetersSpecial Documentation (SD) -
Proline Promass 300
HART
OPC-UA Server application package
for IIoT and SCADA applications
Special Documentation
Special Documentation
OPC-UA Server
For IIoT and SCADA applicationsSpecial Documentation (SD) -
Proline Promass 300
EtherNet/IP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promass 300
PROFINET
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 300
PROFIBUS DP
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Display modules A309/A310
Display with WLAN interface
Special Documentation
Special documentation
Display modules A309/A310
Display with WLAN interfaceSpecial Documentation (SD) -
Proline Promass 300
FOUNDATION Fieldbus
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Proline Promass 300
FOUNDATION Fieldbus
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 300
HART
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Proline Promass 300
PROFIBUS PA
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Proline Promass 300
FOUNDATION Fieldbus
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promass 300
HART
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promass 300
EtherNet/IP
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Proline Promass 300
PROFIBUS PA
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promass 300
PROFIBUS PA
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 300
Modbus RS485
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Proline Promass 300
PROFINET
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Proline Promass 300
Modbus RS485
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 300
EtherNet/IP
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 300
Modbus RS485
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promass 300
Functional Safety Manual
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Remote display and operating module DKX001
Special Documentation
Remote display and operating module DKX001
Special Documentation (SD) -
Proline Promass 300
PROFINET
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promass 300 500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promass 300 500 HART: 1.05.00Manufacturer Information (MI) -
Proline Promass 300 / 500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promass 300 / 500 PROFIBUS PA: 1.01.00Manufacturer Information (MI) -
Proline Promass 300 500
Manufacturer information regarding firmware updates (NE 53)
New firmware version:
Promass 300 500 Modbus RS485: 1.01.01Manufacturer Information (MI) -
Proline Promass 300 / 500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promass 300 / 500 Modbus RS485: 1.02.00Manufacturer Information (MI) -
Proline Promass 300 500
Manufacturer information regarding firmware updates (NE 53)
New firmware version:
Promass 300 500 HART: 1.01.01Manufacturer Information (MI) -
Proline 300/500
La technologie de mesure de débit orientée vers l’avenir
Innovations (IN)09/18fr -
Proline 300/500
La tecnología de medición de caudal del futuro
Innovations (IN)05/16Espanhol -
Proline 300/500
American version: The future-oriented flow measuring technology
Innovations (IN)05/16Inglês -
Proline 300/500
Technologie měření průtoku orientovaná na budoucnost
Innovations (IN)05/16Tcheco -
Proline 300/500
La tecnologia di misura della portata orientata al futuro
Innovations (IN)05/16Italiano -
GSD Single, GSD_DP_FL_Promass_300500_0x156F_0x01_0x01, 04.06.2018 (Flow, Promass 300 500, 0x156F)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_PN_FL_Promass300500_0x843B_0x02, 10.09.2019 (Flow, Promass 300 500, 0x843B)
PROFINET,
PROFINET System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_PN_FL_Promass300500_0x843B_0x01_0x01, 16.11.2017 (Flow, Promass 300 500, 0x843B)
PROFINET,
PROFINET System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_PA_FL_Promass300500_0x156D_0x02, 12.11.2018 (Flow, Promass 300 500, 0x156D)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_EH_PA_FL_Promass300_500_0x156D_0x01_0x01, 03.08.2016 (Flow, Promass 300 500, 0x156D)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDS Single, EDS_EIP_FL_Promass_300500_0x103B_0x01_0x01, 27.11.2018 (Flow, Promass 300 500, 0x103B)
EtherNet/IP,
EtherNet IP System Version: AnyElectronic Data Sheet (EDS)1.2Language neutral -
EDD Single, AMS11_HART_FL_Promass300_500_0x113B_0x06_0x01, 30.10.2019 (Flow, Promass 300 500, 0x113
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_FL_Promas300500_0x156F_0x01_0x01, 16.07.2018 (Flow, Promass 300 500, 0x156F)
PROFIBUS DP,
PDM Version: 8.2.1, 9.1.0.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_HART_FL_Promass300_500_0x113B_0x01_0x01, 21.11.2018 (Flow, Promass 300 500, 0x113
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promass300_500_0x113B_0x02_0x01, 27.11.2017 (Flow, Promass 300 500, 0x113B)
HART,
PDM Version: 8.2.1, 9.0.1.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promass300_500_0x003B_0x01_0x01, 03.08.2016 (Flow, Promass 300 500, 0x113B)
HART,
PDM Version: 6.1, 8.2.1, 9.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_FF_FL_Promass_300500_0x103B_0x01_0x01, 15.03.2017 (Flow, Promass 300 500, 0x103B)
FOUNDATION Fieldbus H1,
AMS Version: 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EDD_FF_FL_Promass300500_0x103B_0x01_0x01, 29.09.2017 (Flow, Promass 300 500, 0x103B)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promass300_500_0x113B_0x02_0x01, 28.11.2017 (Flow, Promass 300 500, 0x113B)
HART,
Experion Version: R432.1
Field Device Manager Version: R450.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promass300_500_0x113B_0x06_0x01, 28.10.2019 (Flow, Promass 300 500, 0x113B)
HART,
Experion Version: R500
Field Device Manager Version: R500Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_Promass300_500_0x156D_0x01_0x01, 03.08.2016 (Flow, Promass 300 500, 0x156D)
PROFIBUS PA,
PDM Version: 6.1, 8.2.1, 9.0, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promass300_500_0x113B_0x06_0x01, 30.10.2019 (Flow, Promass 300 500, 0x113
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5, 14.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promass300_500_0x003B_0x01_0x01, 03.08.2016 (Flow
, Promass 300 500, 0x113B)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FCx75_HART_FL_Promass300500_0x113B_0x01_0x01, 17.02.2017 (Flow, Promass 300 500, 0x113B)
HART, Package: Package, Variant: Variant
FC475 Version: 2.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promass300_500_0x113B_0x06_0x01, 20.11.2019 (Flow, Promass 300 500, 0x113B)
HART,
PDM Version: 8.2.1, 9.1.0.4Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PN_FL_Promass300_500_0x843B_0x02_0x01, 20.09.2019 (Flow, Promass 300 500, 0x843B)
PROFINET,
PDM Version: 8.2.1, 9.1.0.4Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_FF_FL_Promass_300500_0x103B_0x01_0x01, 15.03.2017 (Flow, Promass 300 500, 0x103B)
FOUNDATION Fieldbus H1,
AMS Version: 11.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_FF_FL_Promass_300500_0x103B_0x01_0x01, 17.03.2017 (Flow, Promass 300 500, 0x103B)
FOUNDATION Fieldbus H1,
AMS Version: 10.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PN_FL_Promass300_500_0x843B_0x01_0x01, 27.11.2017 (Flow, Promass 300 500, 0x843B)
PROFINET,
PDM Version: 8.2.1, 9.0.1.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promass300_500_0x113B_0x02_0x01, 22.11.2018 (Flow, Promass 300 500, 0x113
HART,
AMS Version: 11.0, 11.1, 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promass300_500_0x113B_0x02_0x01, 22.11.2018 (Flow, Promass 300 500, 0x113
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5, 14.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS13_FF_FL_Promass_300500_0x103B_0x01_0x01, 15.03.2017 (Flow, Promass 300 500, 0x103B)
FOUNDATION Fieldbus H1,
AMS Version: 13.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_Promass300500_0x156D_0x02_0x01, 18.01.2019 (Flow, Promass 300 500, 0x156D)
PROFIBUS PA,
PDM Version: 8.1, 9.1.0.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promass300_500_0x113B_0x01_0x01, 21.11.2018 (Flow, Promass 300 500, 0x113
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Promass_300_500_0x103B_FF_FW1_00_zz_Dev_Rev_01, 09.07.2019 (Flow, Promass 300 500, 0x10
FOUNDATION Fieldbus H1,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.06.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
PACTware Version: 4.1
Plant Resource Manager Version: R3.20Device Type Manager (DTM)1.9.0.197Language neutral -
DTM Single, Promass_300_500_0x003B_FW_1_00_zz_Dev_Rev_1, 09.07.2019 (Flow, Promass 300 500, 0x113B)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.8.0.224Language neutral -
DTM Single, Promass_300_500_MR4-CDIE_FW_1_00_zz_Dev_Rev_1, 13.07.2019 (Flow, Promass 300 500, 0x643
Modbus RS485,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.8.0.139Language neutral -
DTM Single, Promass_300_500_8x3x_8x5x_FW_1_00_zz_Dev_Rev_1, 09.07.2019 (Flow, Promass 300 500, 0x15
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.8.0.128Language neutral -
DTM Single, Promass_300_500_HART_FW_1_05_zz_Dev_Rev_06, 04.10.2019 (Flow, Promass 300 500, 0x113B)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.03.00
Field Device Manager Version: R500
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
PACTware Version: 5.0 SP4
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.39.0.627Language neutral -
DTM Single, Promass_300_500_MR4-CDIE_FW_1_05_zz_Dev_Rev_06, 04.10.2019 (Flow, Promass 300 500, 0x64
Modbus RS485,
DeviceCare Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.39.0.289Language neutral -
DTM Single, Promass_300_500_MR4_FW_1_05_00_Dev_Rev_06, 04.10.2019 (Flow, Promass 300 500, 0x643B)
Modbus RS485,
DeviceCare Version: 1.03.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.39.0.289Language neutral -
DTM Single, Promass300500_PN-CDIE_FW_1_01_zz_Dev_Rev_02, 16.09.2019 (Flow, Promass 300 500, 0x843B)
PROFINET,
DeviceCare Version: 1.05.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.39.0.222Language neutral -
DTM Single, Promass_300_500_8x3x-8x5x_FW_1_01_zz_Dev_Rev_02, 09.07.2019 (Flow, Promass 300 500, 0x1
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
PACTware Version: 5.0Device Type Manager (DTM)1.12.0.193Language neutral -
DTM Single, Promass_300_500_DP_FW_1_00_zz_Dev_Rev_01, 10.07.2019 (Flow, Promass 300 500, 0x156F)
PROFIBUS DP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
PACTware Version: 5.0Device Type Manager (DTM)1.11.0.93Language neutral -
DTM Single, Promass_300_500_EIP-CDIE_FW_1_00_zz_Dev_Rev_01, 13.07.2019 (Flow, Promass 300 500, 0x10
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.10.0.94Language neutral -
DTM Single, Promass_300_500_EIP_FW_1_00_zz_Dev_Rev_01, 13.07.2019 (Flow, Promass 300 500, 0x103B)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
Unity Pro XL Version: 12.0Device Type Manager (DTM)1.10.0.94Language neutral -
DTM Single, Promass_300_500_HART_FW_1_01_zz_Dev_Rev_02, 09.07.2019 (Flow, Promass 300 500, 0x113B)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.06.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
PACTware Version: 5.0
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.10.0.441Language neutral -
DTM Single, Promass_300_500_MR4-CDIE_FW_1_01_zz_Dev_Rev_2, 13.07.2019 (Flow, Promass 300 500, 0x643
Modbus RS485,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.10.0.237Language neutral -
DTM Single, Promass_300_500_MR4_FW_1_01_zz_Dev_Rev_02, 13.07.2019 (Flow, Promass 300 500, 0x643B)
Modbus RS485,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.10.0.237Language neutral -
DTM Single, Promass300500_PN-CDIE_FW_1_00_zz_Dev_Rev_01, 13.07.2019 (Flow, Promass 300 500, 0x843B)
PROFINET,
FieldCare Version: 2.13.00Device Type Manager (DTM)1.10.0.115Language neutral -
AOP Single, RS_EIP_FL_Promass300500_0x103B_0x01_0x01_AOP, 28.08.2019 (Flow, Promass 300 500, 0x103B)
EtherNet/IP,
RA RSLogix 5000 Version: V20.04and later
RA Studio 5000 Version: V21 and laterAdd On Profile (AOP)1.19Language neutral -
Faceplate Single, PRM_FF_FL_Promass_300500_0x103B_0x01_0x01, 15.03.2017 (Flow, Promass 300 500, 0x1
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.20Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Promass300_500_0x113B_0x06_0x01, 28.10.2019 (Flow, Promass 300 500, 0
HART,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Promass300_500_0x003B_0x01_0x01, 03.08.2016 (Flow, Promass 300 500, 0
HART,
Plant Resource Manager Version: R3.12Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Promass300_500_0x113B_0x02_0x01, 28.11.2017 (Flow, Promass 300 500, 0
HART,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_Modbus_RS485, 25.10.2019 (Flow)
Modbus RS485,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.03Language neutral -
Verification DTM Library, VerificationDTM_FLOW_EIP, 25.10.2019 (Flow)
EtherNet/IP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.03Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_PA, 25.10.2019 (Flow)
PROFIBUS PA,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.03Language neutral -
Verification DTM Library, VerificationDTM_FLOW_FOUNDATION_Fieldbus, 25.10.2019 (Flow)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.03Language neutral -
Verification DTM Library, VerificationDTM_FLOW_ProfiNet, 25.10.2019 (Flow)
PROFINET,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.03Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 25.10.2019 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.03Language neutral -
Promass S, Promass P, Promass I, Promass F, Promass A, Promass 84, Promass 83, Promass 80, Promag H, Promag 55, Promag 53, Promag 50, Promag 10
Código do Produto: 8A1B-, 8A3B-, 8A5B-, 8F1B-, 8F2B-, 8F3B-, 8F5B-, 8I1B-, 8I3B-, 8I5B-, 8P1B-, 8P3B-, 8P5B-, 8S1C-, 8S3B-, 8S5B-, 84F-, 84A-, 83S-, 83P-, 83I-, 83F-, 83A-, 80S-, 80P-, 80I-, 80F-, 80A-, 55H-, 53H-, 50H-, 10H-
Número declaração: HE_00912_01.17
especificação do fabricante: EHEDG, Food hygieneManufacturer DeclarationAlemão , Inglês -
Dosimass OEM, Promass 40, Promass 80, Promass 83, Promass 84, Promass A, Promass E, Promass F, Promass Q
Código do Produto: 8E3B-, 8E5B-, 8F1B-, 8F2B-, 8F3B-, 8F5B-, 8PE-, 8Q3B-, 8Q5B-, 8RE-, O8E1B-, O8E1C-, O8E3B-, O8E5B-, O8F1B-, O8F3B-, O8F5B-, O8Q3B-, O8Q5B-, 8E2B-, 8E1C-, 8E1B-, 8BE-, 8A5C-, 8A5B-, 8A3C-, 8A3B-, 8A2B-, 8A1B-, 84F-, 84A-, 83F-, 83E-, 83A-, 80F-, 80E-, 80A-, 40E-
Número declaração: HE_00351_03.16
especificação do fabricante: Food hygiene, 1935/2004Manufacturer DeclarationInglês -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A
Código do Produto: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Número declaração: EC_00405_06.16EU DeclarationAlemão , Inglês -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A
Código do Produto: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Número declaração: EC_00406_04.16EU DeclarationAlemão , Inglês -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A
Código do Produto: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Número declaração: EC_00405_07.16EU DeclarationAlemão , Inglês -
Promass F, Promass E, Promass X, Promass O, Promass I, Promass Q, Promass A, Promass S, Promass P, Promass H
Código do Produto: 8Q5B-, 8F5B-, 8I5B-, 8E5B-, 8X5B-, 8S5B-, 8O5B-, 8P5B-, 8H5B-, 8Q3B-, 8A5B-, 8I3B-, 8F3B-, 8O3B-, 8E3B-, 8X3B-, 8P3B-, 8S3B-, 8H3B-, 8A3B-, 8A5C-, 8A3C-
Número declaração: EC_00424_04.16EU DeclarationAlemão , Inglês -
Promass X, Promass F, Promass E, Promass 83, Promass P, Promass S, Promass I, Promass O, Promass H, Promass A, Promass 84, Promass 80, Promass 40
Código do Produto: 8E1B-, 83F-, 83E-, 83H-, 83I-, 83P-, 83M-, 83S-, 83A-, 8F2B-, 8F1B-, 8I1B-, 8S1B-, 83O-, 83X-, 8A1B-, 80F-, 80E-, 80H-, 8E2B-, 80I-, 84F-, 80P-, 80S-, 8O1B-, 80A-, 8P5B-, 8I5B-, 8H5B-, 8S5B-, 8F5B-, 8F3B-, 8E3B-, 8E5B-, 8S3B-, 8I3B-, 8O3B-, 8P3B-, 8H3B-, 8X3B-, 84A-, 8A5B-, 8A3B-, 40E-, 8X5B-, 8S1C-, 8E2C-, 84X-, 8A5C-, 8A3C-
Região: Russia (TR CU)
Agente Certificador: EAC
Número da Certificação: TC RU D-CH.MU62.B.02333MiscellaneousRusso -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Promass 84, Promass 83, Promass 80
Código do Produto: 8I5B-, 8O1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q1B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X1B-, 8X3B-, 8X5B-, O8X5B-, 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8H1B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8A5B-, 8A3B-, 8A1B-
Região: Russia (TR CU)
Agente Certificador: EAC
Número da Certificação: TC № RU D-CH.MU62.B.02411MiscellaneousRusso -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Código do Produto: O8X3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-, 8X3B-, 8S3B-, 8Q3B-, 8P3B-, 8O3B-, 8I3B-, 8H3B-, 8F3B-, 8E3B-, 8C3B-, 8A3B-
Região: China
Agente Certificador: NEPSI
Categoria: zone 2Explosion ProtectionChinês -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Código do Produto: 8Q3B-, 8Q5B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5B-, 8A3B-
Região: South Africa
Agente Certificador: SABS
Categoria: zone 1, zone 2, zone 0, zone 21,22Explosion ProtectionInglês -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Código do Produto: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5B-, 8A3B-
Região: India
Agente Certificador: CC(O)E
Categoria: zone 1Explosion ProtectionInglês -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Código do Produto: O8X3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-, 8X3B-, 8S3B-, 8Q3B-, 8P3B-, 8O3B-, 8I3B-, 8H3B-, 8F3B-, 8E3B-, 8C3B-, 8C1B-, 8A3C-, 8A3B-
Região: International (IECEx)
Agente Certificador: CSA
Proteção: Ex ecExplosion ProtectionInglês -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Código do Produto: O8X3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-, 8X3B-, 8S3B-, 8Q3B-, 8P3B-, 8O3B-, 8I3B-, 8H3B-, 8F3B-, 8E3B-, 8C3B-, 8A3B-, 8A3C-
Região: China
Agente Certificador: NEPSI
Categoria: zone 21, zone 0,1Explosion ProtectionChinês -
Promass F, Promass E, Promass A, Promass O, Promass X, Promass I, Promass Q, Promass P, Promass S, Promass H
Código do Produto: 8Q3B-, 8F3B-, 8O3B-, 8E3B-, 8X3B-, 8I3B-, 8P3B-, 8S3B-, 8H3B-, 8A3B-, 8A3C-, O8X3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-
Região: Brazil
Agente Certificador: INMETRO
Categoria: zone 2
Proteção: Ex ecExplosion ProtectionPortuguês -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Código do Produto: 8P5B-, 8Q3B-, 8Q5B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8A3B-, 8A3C-, 8A5B-, 8A5C-, 8C3B-, 8C5B-, 8E3B-, 8E5B-, 8F3B-, 8F5B-, 8H3B-, 8H5B-, 8I3B-, 8I5B-, 8O3B-, 8O5B-, 8P3B-
Região: USA, Canada
Agente Certificador: CSA
Categoria: I/2/A,B,C,DExplosion ProtectionInglês -
Promass A, Promass F, Promass E, Promass P, Promass I, Promass S, Promass H, Promass O, Promass Q, Promass X
Código do Produto: 8Q5B-, 8P5B-, 8I5B-, 8S5B-, 8O5B-, 8H5B-, 8F5B-, 8F3B-, 8S3B-, 8E5B-, 8E3B-, 8P3B-, 8O3B-, 8I3B-, 8H3B-, 8Q3B-, 8X3B-, 8A5B-, 8A3B-, 8X5B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8A3C-, 8A5C-
Região: Russia, Russia (TR CU)
Agente Certificador: EAC
Proteção: Ex tb [ia Da] IIIC Txxx°C Db, Ex nA [ia Ga] IIC T5 Gc, Ex d e [ia Ga] IIC IIC Gb, Ex d e [ia Ga] IIB IIB Gb, Ex d [ia Ga] IIC T6...T1 Gb, Ex d [ia Ga] IIC T6...T1 Ga/Gb, Ex tb IIIC Txxx°C Db, Ex nA IIIC IIIC Gc, Ex nA IIC T6...T1 Gc, Ex ia IIC T6...T1 Gb, Ex ia IIC T6...T1 Ga/Gb, Ex ia IIB T6...T1 Gb, Ex ia IIB T6...T1 Ga/Gb, Ex d IIC T6...T1 Gb, Ex d IIC T6...T1 Ga/Gb, [Ex ia] IIIC, [Ex ia] IICExplosion ProtectionRusso -
Cubemass C, Promass F, Promass E, Promass P, Promass I, Promass S, Promass H, Promass O, Promass A, Promass Q, Promass X
Código do Produto: O8X3B-, 8F3B-, 8S3B-, 8E3B-, 8P3B-, 8O3B-, 8I3B-, 8H3B-, 8Q3B-, 8X3B-, 8A3B-, 8C3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-
Região: China
Agente Certificador: NEPSI
Categoria: zone 21, zone 0,1Explosion ProtectionChinês -
Promass F, Promass E, Promass A, Promass O, Promass X, Promass Q, Promass I, Promass P, Promass S, Promass H, Cubemass C
Código do Produto: 8Q3B-, 8F3B-, 8O3B-, 8E3B-, 8X3B-, 8I3B-, 8P3B-, 8S3B-, 8H3B-, 8A3B-, 8C3B-
Região: South Korea
Agente Certificador: KTL
Categoria: zone 1, zone 21
Proteção: Ex d [ia], Ex tbExplosion Protection -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Código do Produto: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Região: USA, Canada
Agente Certificador: CSA
Categoria: I/2/A,B,C,D T6...T1, I/2/A,B,C,D A,B,C,D, I/2/A,B,C,DExplosion ProtectionInglês -
Promass F, Promass E, Promass A, Promass O, Promass X, Promass Q, Promass I, Promass P, Promass S, Promass H
Código do Produto: 8Q3B-, 8F3B-, 8O3B-, 8E3B-, 8X3B-, 8I3B-, 8P3B-, 8S3B-, 8H3B-, 8A3B-, 8A3C-, O8X3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-
Região: Brazil
Agente Certificador: INMETRO
Categoria: zone 1, zone 21, zone 0,1
Proteção: Ex ia, Ex tb, Ex db eb, Ex dbExplosion ProtectionPortuguês -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Código do Produto: O8X3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-, 8X3B-, 8S3B-, 8Q3B-, 8P3B-, 8O3B-, 8I3B-, 8H3B-, 8F3B-, 8E3B-, 8C3B-, 8A3B-, 8A3C-
Região: China
Agente Certificador: NEPSI
Categoria: zone 2Explosion ProtectionChinês -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Código do Produto: O8X3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-, 8X3B-, 8S3B-, 8Q3B-, 8P3B-, 8O3B-, 8I3B-, 8H3B-, 8F3B-, 8E3B-, 8C3B-, 8A3C-, 8A3B-
Região: International (IECEx)
Agente Certificador: CSA
Proteção: Ex tb, Ex db eb, Ex dbExplosion ProtectionInglês -
Promass F, Promass E, Promass A, Promass O, Promass X, Promass I, Promass Q, Promass P, Promass S, Promass H, Cubemass C
Código do Produto: 8Q3B-, 8F3B-, 8O3B-, 8E3B-, 8X3B-, 8I3B-, 8P3B-, 8S3B-, 8H3B-, 8C3B-, 8A3B-, 8A3C-, O8X3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-
Região: Japan
Agente Certificador: CMLExplosion ProtectionJaponês -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Código do Produto: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Região: USA, Canada
Agente Certificador: CSA
Categoria: I,II,III/1/A,B,C,D,E,F,G T6...T1, I,II,III/1/A,B,C,D,E,F,G A,B,C,D,E,F,G, I,II,III/1/C,D,E,F,G T6...T1, I,II,III/1/C,D,E,F,G C,D,E,F,GExplosion ProtectionInglês -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Código do Produto: O8X3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-, 8X3B-, 8S3B-, 8Q3B-, 8P3B-, 8O3B-, 8I3B-, 8H3B-, 8F3B-, 8E3B-, 8C3B-, 8A3C-, 8A3B-
Região: Europe (ATEX)
Agente Certificador: SIRA
Proteção: Ex tb, Ex db eb ia, Ex dbExplosion ProtectionInglês -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Código do Produto: 8P5B-, 8Q3B-, 8Q5B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Região: India
Agente Certificador: CC(O)E
Categoria: zone 1,2Explosion ProtectionInglês -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Código do Produto: 8P5B-, 8Q3B-, 8Q5B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8A3B-, 8A3C-, 8A5B-, 8A5C-, 8C3B-, 8C5B-, 8E3B-, 8E5B-, 8F3B-, 8F5B-, 8H3B-, 8H5B-, 8I3B-, 8I5B-, 8O3B-, 8O5B-, 8P3B-
Região: Canada, USA
Agente Certificador: CSA
Categoria: I/1/A,B,C,D,E,F,G, I/1/A,B,C,D, I/1/C,D,E,F,GExplosion ProtectionInglês -
Promass A, Promass E, Promass F, Promass I, Promass K, Promass P, Promass Q, Promass S
Código do Produto: 8I5B-, 8K1B-, 8P1B-, 8P3B-, 8P5B-, 8Q1B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8I3B-, 8I1B-, 8F5B-, 8F3B-, 8F1B-, 8E5B-, 8E3B-, 8E1C-, 8E1B-, 8A5B-, 8A3B-, 8A1B-
Região: USA
Agente Certificador: 3-A Sanitary StandardsHygienic EquipmentInglês -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Código do Produto: O8O5B-, O8O3B-, 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5B-, 8A3B-
Região: International
Agente Certificador: PI, PROFIBUS InternationalFieldbus ConformanceInglês -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Código do Produto: 8A3B-, 8C3B-, 8E3B-, 8F3B-, 8H3B-, 8I3B-, 8O3B-, 8P3B-, 8Q3B-, 8S3B-, 8X3B-, 8A3C-
Região: International
Agente Certificador: OPC Foundation
Versão do software: 01.01.03Fieldbus ConformanceInglês -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A
Código do Produto: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Região: International
Agente Certificador: ODVA
Versão do software: 01.00.04Fieldbus ConformanceInglês -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Código do Produto: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5B-, 8A3B-
Região: International
Agente Certificador: FieldComm Group
Versão do software: 01.01.01Fieldbus ConformanceInglês -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Código do Produto: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5B-, 8A3B-
Região: International
Agente Certificador: PI, PROFIBUS InternationalFieldbus ConformanceInglês -
Promass F, Promass O, Promass E, Promass X, Promass I, Promass Q, Promass P, Promass A, Promass S, Promass H, Cubemass C
Código do Produto: 8Q5B-, 8F5B-, 8O5B-, 8I5B-, 8E5B-, 8X5B-, 8S5B-, 8P5B-, 8H5B-, 8Q3B-, 8F3B-, 8A5B-, 8I3B-, 8O3B-, 8E3B-, 8X3B-, 8P3B-, 8S3B-, 8H3B-, 8A3B-, 8C5B-, 8C3B-
Região: International
Agente Certificador: FieldComm GroupFieldbus ConformanceInglês -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Código do Produto: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5B-, 8A3B-
Região: International
Agente Certificador: PI, PROFIBUS InternationalFieldbus ConformanceInglês -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Código do Produto: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Região: International
Agente Certificador: FieldComm Group
Versão do software: 01.05.00Fieldbus ConformanceInglês -
Promass F, Promass E, Promass A, Promass O, Promass X, Promass Q
Código do Produto: 8Q5B-, 8F5B-, 8O5B-, 8E5B-, 8X5B-, 8A5B-, 8Q3B-, 8F3B-, 8O3B-, 8E3B-, 8X3B-, 8A3B-
Região: Singapore
Agente Certificador: Spring
Número da Certificação: WMO/PA/377MetrologyInglês -
Promass F, Promass E, Promass O, Promass A, Promass X, Promass Q, Promass I, Promass P, Promass S, Promass H, Promass G, Promass 84, Promass 83, Promass 80, Promass 40
Código do Produto: 8Q5B-, 8F5B-, 8O5B-, 8E5B-, 8X5B-, 8I5B-, 8S5B-, 8P5B-, 8H5B-, 8Q3B-, 8A5B-, 8F3B-, 8O3B-, 8E3B-, 8I3B-, 8P3B-, 8S3B-, 8H3B-, 8A3B-, 8F1B-, 8I1B-, 8P1B-, 8A1B-, 8E1B-, 8H1B-, 8O1B-, 8S1B-, 8G1B-, 8S1C-, 8F2B-, 8E2B-, 83F-, 83E-, 8E1C-, 83A-, 83I-, 83S-, 83H-, 83P-, 8E2C-, 80F-, 83O-, 83X-, 80E-, 80A-, 80I-, 80P-, 80S-, 40E-, 80H-, 84X-, 84O-, 84F-, 84A-
Região: Uzbekistan
Agente Certificador: UZS
Número da Certificação: 02.6721MetrologyRusso -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A
Código do Produto: 8X5B-, 8X3B-, 8X1B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8A5B-, 8A3B-
Região: Russia
Agente Certificador: Rosstandart
Número da Certificação: CH.C.29.004.A № 66949MetrologyRusso -
Promass F, Promass E, Promass A, Promass O, Promass X, Promass Q
Código do Produto: 8Q5B-, 8F5B-, 8O5B-, 8E5B-, 8X5B-, 8A5B-, 8Q3B-, 8F3B-, 8O3B-, 8E3B-, 8X3B-, 8A3B-
Região: Singapore
Agente Certificador: Spring
Número da Certificação: WMO/PA/376MetrologyInglês -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A
Código do Produto: 8X5B-, 8X3B-, 8X1B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8A5B-, 8A3B-
Região: Russia
Agente Certificador: Rosstandart
Número da Certificação: CH.C.29.004.A № 66949MetrologyRusso
Acessórios / peças sobressalentes
-
-
Nr 31 Order code 71323007
Kit power supply, 100-230VAC, Ex
Usage: Promag/Promass 300/500, Prosonic Flow 300, transmitter housing, electronic compartment.
-
Nr 31 Order code 71323008
Kit power supply, 24VDC, Ex
Usage: Promag/Promass 300/500, Prosonic Flow 300, transmitter housing, electronic compartment.
-
Nr 31 Order code 71323009
Kit pow.supply,100-230VAC/24VDC, Non-haz
Usage: Promag/Promass/Prosonic Flow 300/500 digital. Non-haz, Zone 2, transmitter housing, electronic compartment.
-
-
-
Nr 39 Order code 71185788
Kit T-DAT, 100/300/400/500/500 digital
Usage: Promag/Promass 100/300/500, 500 digital, Prosonic Flow E 100, Prosonic Flow 300, 500 digital, Promag 400(C). (C) = generation index C.
-
-
-
Nr 33 Order code XPD0028-
ISEM electronic module, Promass 300/500
Usage: Promass, Cubemass 300/500
-
-
-
Nr 37 Order code 71323010
Kit module cartridge, 300/500, Ex
Usage: transmitter housing, electronic compartment. Consists of: module cartridge incl. interconnection board.
-
-
-
Nr 34 Order code XPD0037-
-
-
-
Nr 37 Order code 71323011
Kit module cartridge, 300, Non-haz
Usage: transmitter housing, electronic compartment. Consists of: module cartridge incl. interconnection board.
-
-
-
Nr 46 Order code 71323005
-
-
-
Nr 35 Order code XPD0038-
-
-
-
Nr 45 Order code 71323073
Kit conn.terminal option A, 300, Non-haz
Usage: transmitter housing Alu/hygienic, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol.
-
-
-
Nr 50 Order code XPD0031-
-
-
-
Nr 45 Order code 71323074
Kit conn.terminal option B, 300, Non-haz
Usage: transmitter housing Alu/hygienic, connection compartment. Option B = EtherNet, PROFINET. Consists of: 1x connection terminal 3-Pol., 1x connection terminal 4-Pol.
-
Nr 45 Order code 71327818
Kit conn.terminal option C, 300, Non-haz
Usage: transmitter housing Alu/hygienic, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol.
-
Nr 45 Order code 71323075
Kit conn.terminal option A, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol.
-
Nr 45 Order code 71323076
Kit conn.terminal option B, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option B = EtherNet, PROFINET. Consists of: 2x connection terminal 2-Pol.
-
Nr 45 Order code 71327819
Kit conn.terminal option C, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol.
-
-
-
Nr 49 Order code 71323079
Kit terminal, transm.,remote display,300
Usage: transmitter housing Alu/cast, connection compartment with remote display DKX001. Consists of: 1x connection terminal 4-Pol.
-
-
-
Nr 20 Order code 71323016
Kit cover, sight glass, Alu,Non-haz/Exde
Usage: Promag/Promass/Prosonic Flow 300, transmitter housing Alu, Non-haz. Promag/Promass 300/500, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110.7x3.53 HNBR.
-
Nr 20 Order code 71323017
Kit cover,glass, Alu, -50oC,Non-haz/Exde
Usage: Promass/Prosonic Flow 300, transmitter housing Alu, Non-haz. Promag 500, Promass 300/500, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 21 Order code 71323018
Kit cover, blind, Alu, Non-haz/Exde
Usage: Promag/Promass/Prosonic Flow 300, transmitter housing Alu, Non-haz. Promag/Promass/Prosonic Flow 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 110,7x3,53 HNBR.
-
Nr 21 Order code 71323019
Kit cover, blind, Alu,-50oC,Non-haz/Exde
Usage: Promass/Prosonic Flow 300, transmitter housing Alu, Non-haz. Promass/Prosonic Flow 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 20 Order code 71323020
Kit cover, sight glass, Alu, Exd
Usage: Promag/Promass 300/500, Prosonic Flow 300, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110.7x3.53 HNBR.
-
Nr 20 Order code 71323021
Kit cover, sight glass, Alu, -50oC, Exd
Usage: Promag 500, Promass 300/500, Prosonic Flow 300, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 21 Order code 71323022
Kit cover, blind, Alu, Exd
Usage: Promag/Promass/Prosonic Flow 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 110,7x3,53 HNBR.
-
Nr 21 Order code 71323023
Kit cover, blind, Alu, -50oC, Exd
Usage: Promass/Prosonic Flow 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 70 Order code 71323026
Kit cover gasket, sight glass/blind
Usage: Promag/Promass 300/500, Prosonic Flow 300, transmitter housing Alu/cast. Consists of: 10x O-Ring 110.7x3.53 HNBR.
-
Nr 70 Order code 71323027
Kit cover gasket,sight glass/blind,-50oC
Usage: Promag 500, Promass 300/500, Prosonic Flow 300, transmitter housing Alu/cast, Consists of: O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 22 Order code 71323028
Kit cover, electr.compart., Alu, Non-haz
Usage: Promag/Promass/Prosonic Flow 300, transmitter housing Alu, Non-haz. Consists of: cover Alu, O-Ring 117,1x3,53 HNBR.
-
Nr 22 Order code 71323029
Kit cover,electronic, Alu,- 50oC,Non-haz
Usage: Promass/Prosonic Flow 300, transmitter housing Alu, Non-haz. Consists of: cover Alu, O-Ring 117,1x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 74 Order code 71323030
Kit cover gasket,electr.compart.,Non-haz
Usage: Promag/Promass/Prosonic Flow 300, transmitter housing Alu, Non-haz. Consists of: 10x O-Ring 117,1x3,53 HNBR.
-
Nr 74 Order code 71323031
Kit cover gasket,electr., -50oC, Non-haz
Usage: Promass/Prosonic Flow 300, transmitter housing Alu, Non-haz. Consists of: O-Ring 117,1x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 22 Order code 71323032
Kit cover, electronic compart., Alu, Ex
Usage: Promag/Promass 300/500, Prosonic Flow 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 120,2x3,53 HNBR.
-
Nr 22 Order code 71323033
Kit cover, electr.compart., Alu,-50oC,Ex
Usage: Promag 500, Promass 300/500, Prosonic Flow 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 74 Order code 71323036
Kit cover gasket, electronic compart.,Ex
Usage: Promag/Promass 300/500, Prosonic Flow 300, transmitter housing Alu/cast, Ex. Consists of: 10x O-Ring 120,2x3,53 HNBR.
-
Nr 74 Order code 71323037
Kit cover gasket,elect.compart.,-50oC,Ex
Usage: Promag 500, Promass 300/500, Prosonic Flow 300, transmitter housing Alu/cast, Ex. Consists of: O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 28 Order code 71323044
Kit cover, remote display, Alu
Usage: Remote display DKX001, housing Alu. Consists of: cover Alu, O-Ring 88,50x3,53 HNBR.
-
Nr 28 Order code 71323045
Kit cover, remote display, Alu, -50oC
Usage: Remote display DKX001, housing Alu. Consists of: cover Alu, O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 76 Order code 71323048
Kit cover gasket, remote display
Usage: Remote display DKX001, housing Alu/cast. Consists of: 10x O-Ring 88,50x3,53 HNBR.
-
Nr 76 Order code 71323049
Kit cover gasket, remote display, -50oC
Usage: Remote display DKX001, housing Alu/cast. Consists of: O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 71 Order code 71323071
Kit interface gaskets, 300/500
Usage: Promass 300/500, Prosonic Flow 300, transmitter housing/sensor or transmitter housing/wall mount. Consists of: 5x O-Ring 88,50x3,53 HNBR for interface.
-
Nr 71 Order code 71323072
Kit interface gaskets, 300/500, -50oC
Usage: Promass 300/500, Prosonic Flow 300, transmitter housing/sensor or transmitter housing/wall mount. Consists of: O-Ring 88,50x3,53 FVMQ for interface, -50oC/-58oF.
-
Nr 71 Order code 71368491
Kit interface gaskets, Promass 300, hyg.
Usage: transmitter housing/sensor. Consists of: 5x O-Ring 88,50x3,53 HNBR for interface, 5x gasket EPDM for interface.
-
-
-
Nr 11 Order code 71368488
Kit protective cover optionA,300,Non-haz
Usage: transmitter housing Alu/hygienic, connection compartment. Option A = HART, PROFIBUS PA, PROFIBUS DP, Modbus RS485, FOUNDATION Fieldbus. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
Nr 11 Order code 71368489
Kit protective cover optionB,300,Non-haz
Usage: transmitter housing Alu/hygienic, connection compartment. Option B = EtherNet, PROFINET. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
Nr 11 Order code 71323081
Kit protective cover option A,300/500,Ex
Usage: transmitter housing Alu/cast, connection compartment. Option A = HART, PROFIBUS PA, PROFIBUS DP, Modbus RS485, FOUNDATION Fieldbus. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
Nr 11 Order code 71323082
Kit protective cover option B,300/500,Ex
Usage: transmitter housing Alu/cast, connection compartment. Option B = EtherNet, PROFINET. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
-
-
Nr 87 Order code 71343505
Kit weather protection cover, 300/500
Usage: Promag/Promass 300/500, Prosonic Flow 300, transmitter housing. Consists of: weather protection cover 4404, installation material.
-
-
-
Order code 71351317
Kit wireless antenna extended range
Consists of: Connection cable in the transmitter, Ex cable entry for antenna, 1.5m cable, antenna, angle with union nut.
-
Order code 8X3BXX-
-
Order code DKS-
-
Order code DK8MS-
Promass A, Mounting Kit
Adapters to different process connections. For connecting to the Cajon 4-VCO-4 couplings. Set includes two adapters.
-
Order code DK8AS-
Promass A, post mounting kit
-
Order code DKX001-
Remote Display DKX001
-
Order code DKX002-
Connection Cable for Remote Display
Connection Cable for Remote Display DKX001 of Proline 300.
-
Order code XPRFID-
-
-
Successor