Especificações resumidas
-
Measurement range
Trace: 0 to 5 mg/l HOCl
Standard: 0 to 20 mg/l HOCl -
Process temperature
+0 to 55 °C (32 to 130°F), non-freezing
-
Process pressure
1 bar (14.5 psi)
-
Measuring method
- Closed, membrane covered measuring cell
- Reduction of free chlorine at the cathode
Campo de aplicação
CCS51 is a robust, low-maintenance sensor for free chlorine. It provides high-precision measurement with long-term stability in drinking water, pool and process water and ensures consistent disinfection monitoring even at low water volumes. The analog free chlorine sensor features extremely fast response times guaranteeing efficient process control and safe processes. CCS51 ensures continuity for the installed base of analog free chlorine measuring points.
CCS51 is an analog free chlorine sensor for skid builders and end customers. It measures reliably in:
Drinking water - to ensure reliable disinfection
Process water - for hygienic and safe packaging and bottling of products
Utilities - to detect the absence or presence of free chlorine
Pool water - to dose disinfectant efficiently
Benefícios
-
Fast response time (t90 < 25 s) provides accurate process view and enables prompt reaction to process changes as well as efficient process control.
Increased process safety: precise and long-term stable measurement ensures consistent process monitoring and allows for individually adapted disinfectant dosing.
The low-maintenance, amperometric sensor reduces the cost of ownership of the measuring point, particularly compared to colorimetric measuring systems.
Connection to the Liquisys chlorine transmitter ensures continuity for the installed base of analog free chlorine measuring points.
Predecessor
-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade
-
Produtos especializados
- Desenvolvidos para aplicações exigentes
Excelência técnica
Simplicidade
Variável
Versões FLEX | Excelência técnica | Simplicidade |
---|---|---|
Versão Fundamental Atende suas necessidades básicas de medição |
Excelência técnica
|
Simplicidade
|
Versão Lean Lida com seus principais processos facilmente |
Excelência técnica
|
Simplicidade
|
Seleção Extended Otimiza seus processos com tecnologias inovadoras |
Excelência técnica
|
Simplicidade
|
Versão Xpert Controla suas aplicações mais difíceis |
Excelência técnica
|
Simplicidade
Variável |
-
Measuring principle
Free chlorine
-
Application
Drinking water - to ensure reliable disinfection
Process water - wide range of application due to large measuring range
Food - to secure absence/presence of free chlorine
Pool water -efficient dosing thanks to precise measurement -
Characteristic
Amperometric measurement of dissolved free chlorine
-
Measurement range
Trace: 0 to 5 mg/l HOCl
Standard: 0 to 20 mg/l HOCl -
Measuring method
- Closed, membrane covered measuring cell
- Reduction of free chlorine at the cathode -
Design
Closed amperometric 2-electrode measuring cell with PVDF membrane
-
Material
Sensor shaft: POM
Membrane: PVDF
Membrane cap: PVDF -
Dimension
Diameter: 25 mm (0.98 in)
Length: 161 mm (6.34 in) -
Process temperature
+0 to 55 °C (32 to 130°F), non-freezing
-
Process pressure
1 bar (14.5 psi)
-
Temperature sensor
10k NTC
-
Connection
analog with fixed cable
Configurar para baixar os desenhos CAD deste produto
Escolha uma das opções sugeridas
-
-- selected coding-- selected label99.999,00<%label%>
-
Procurando mais opções? Use o configurador individual para continuar.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Procurando mais opções? Use o configurador individual para continuar.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
-
Preço por peça
-
<%range%><%price%>
-
- Acessórios opcionais
Configuração individual
Geralmente são fornecidos juntos
Acessórios
Produtos relacionados