Promass 84M

Imagem de produto: Promass 84M

Esse produto não está mais disponível.

Verifique a nova geração na seção do predecessor / sucessor ou entre em contato com a Endress+Hauser local.

Características e especificações

Voltar

Details

  • Measuring principle

    Coriolis

  • Characteristic / Application

    Coriolis massflow meter for custody transfer application.

  • Ambient temperature

    -20...+65°C
    (-4...+140°F)

  • Process temperature

    -50...+150°C
    (-58...+302°F)

  • Process pressure absolute

    PN 16...100
    PN350 (MP)
    Cl 150...600
    JIS 10...63K

  • Wetted parts

    Titan

  • Output

    4...20mA
    Pulse/Frequency (10KHz, 90° phase shifted, active/passive

  • Certificates / Approvals

    ATEX
    FM
    CSA
    TIIS

  • Measuring principle

    Coriolis

  • Product headline

    Coriolis massflow meter for custody transfer application.

  • Sensor features

    S-DAT, T-DAT
    Validation
    Quick-Set-up
    3 Totalizer
    Pulsating flow

  • Nominal diameter range

    DN 8...25(MP)
    5/16"...3"
    5/16"...1"(MP)

  • Max. measurement error

    Mass flow:+-0.1%
    Volume flow: +-0.25%

  • Measuring range

    0...180'000 kg/h
    0...18'000 kg/h (MP)

  • Max. process pressure

    PN 16...100
    PN350 (MP)
    Cl 150...600
    JIS 10...63K

  • Medium temperature range

    -50...+150°C
    (-58...+302°F)

  • Degree of protection

    IP 67
    NEMA 4x

  • Display/Operation

    Four line backlit
    Touch control

  • Outputs

  • Inputs

    Status

  • Digital communication

    HART

  • Hazardous area approvals

    ATEX
    FM
    CSA
    TIIS

  • Measuring principle

    Coriolis

  • Product headline

    Coriolis massflow meter for custody transfer application.

  • Sensor features

    S-DAT, T-DAT
    Validation
    Quick-Set-up
    3 Totalizer
    Pulsating flow

  • Nominal diameter range

    DN 8...80
    DN 8...25(MP)
    5/16"...3"
    5/16"...1"(MP)

  • Max. measurement error

    Mass flow:+-0.5 %

  • Measuring range

    0...180'000 kg/h
    0...18'000 kg/h (MP)

  • Max. process pressure

    PN 16...100
    PN350 (MP)
    Cl 150...600
    JIS 10...63K

  • Medium temperature range

    -50...+150°C
    (-58...+302°F)

  • Degree of protection

    IP 67
    NEMA 4x

  • Display/Operation

    Four line backlit
    Touch control

  • Outputs

    4...20mA
    Pulse/Frequency (10KHz, 90° phase shifted active/passive

  • Inputs

    Status

  • Digital communication

    HART

  • Hazardous area approvals

    ATEX
    FM
    CSA
    TIIS

Documentos / Manuais / Software

Acessórios / peças sobressalentes

Nr
Order code
Specification
  • Predecessor

  • Successor